Filtered by vendor Broadcom
Subscriptions
Total
647 CVE
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-12679 | 2 Broadcom, Brocade | 2 Sannav, Sannav | 2026-03-03 | 6.5 Medium |
| A vulnerability in Brocade SANnav before 2.4.0b prints the Password-Based Encryption (PBE) key in plaintext in the system audit log file. The vulnerability could allow a remote authenticated attacker with access to the audit logs to access the pbe key. Note: The vulnerability is only triggered during a migration and not in a new installation. The system audit logs are accessible only to a privileged user on the server. These audit logs are the local server VM’s audit logs and are not controlled by SANnav. These logs are only visible to the server admin of the host server and are not visible to the SANnav admin or any SANnav user. | ||||
| CVE-2025-12680 | 2 Broadcom, Brocade | 2 Sannav, Sannav | 2026-03-03 | 4.9 Medium |
| Brocade SANnav before Brocade SANnav 2.4.0b logs database passwords in clear text in the standby SANnav server, after disaster recovery failover. The vulnerability could allow a remote authenticated attacker with admin privilege able to access the SANnav logs or the supportsave to read the database password. | ||||
| CVE-2025-12773 | 2 Broadcom, Brocade | 2 Sannav, Sannav | 2026-03-03 | 6.5 Medium |
| A vulnerability in update-reports-purge-settings.sh script logging for Brocade SANnav before 2.4.0a could allow the collection of SANnav database password in the system audit logs. The vulnerability could allow a remote authenticated attacker with access to the audit logs to access the Brocade SANnav database password. | ||||
| CVE-2025-12774 | 2 Broadcom, Brocade | 2 Sannav, Sannav | 2026-03-03 | 7.5 High |
| A vulnerability in the migration script for Brocade SANnav before 3.0 could allow the collection of database sql queries in the SANnav support save file. An attacker with access to Brocade SANnav supportsave file, could open the file and then obtain sensitive information such as details of database tables and encrypted passwords. | ||||
| CVE-2025-1976 | 1 Broadcom | 1 Fabric Operating System | 2026-02-26 | 6.7 Medium |
| Brocade Fabric OS versions starting with 9.1.0 have root access removed, however, a local user with admin privilege can potentially execute arbitrary code with full root privileges on Fabric OS versions 9.1.0 through 9.1.1d6. | ||||
| CVE-2025-10847 | 1 Broadcom | 1 Unified Infrastructure Management | 2026-02-26 | N/A |
| DX Unified Infrastructure Management (Nimsoft/UIM) and below contains an improper ACL handling vulnerability in the robot (controller) component. A remote attacker can execute commands, read from, or write to the target system. | ||||
| CVE-2025-36553 | 2 Broadcom, Dell | 2 Bcm5820x, Controlvault3 | 2026-02-26 | 8.8 High |
| A buffer overflow vulnerability exists in the CvManager functionality of Dell ControlVault3 prior to 5.15.14.19 and Dell ControlVault3 Plus prior to 6.2.36.47. A specially crafted ControlVault API call can lead to memory corruption. An attacker can issue an api call to trigger this vulnerability. | ||||
| CVE-2025-32089 | 2 Broadcom, Dell | 2 Bcm5820x, Controlvault3 | 2026-02-26 | 8.8 High |
| A buffer overflow vulnerability exists in the CvManager_SBI functionality of Dell ControlVault3 prior to 5.15.14.19 and Dell ControlVault3 Plus prior to 6.2.36.47. A specially crafted ControlVault API call can lead to a arbitrary code execution. An attacker can issue an api call to trigger this vulnerability. | ||||
| CVE-2025-36460 | 3 Broadcom, Dell, Microsoft | 3 Bcm5820x, Controllvault3, Windows | 2026-02-26 | 7.3 High |
| Multiple out-of-bounds read and write vulnerabilities exist in the ControlVault WBDI Driver Broadcom Storage Adapter functionality of Dell ControlVault3 prior to 5.15.14.19 and Dell ControlVault3 Plus prior to 6.2.36.47. A specially crafted WinBioControlUnit call can lead to memory corruption. An attacker can issue an api call to trigger this vulnerability. This vulnerability is triggered when submitting a `WinBioControlUnit` call to the StorageAdapter with the ControlCode 2 (`WBIO_USH_GET_IDENTITY`) with an improper `ReceiveBuferSize` value. | ||||
| CVE-2025-36461 | 2 Broadcom, Dell | 2 Bcm5820x, Controlvault3 | 2026-02-26 | 7.3 High |
| Multiple out-of-bounds read and write vulnerabilities exist in the ControlVault WBDI Driver Broadcom Storage Adapter functionality of Dell ControlVault3 prior to 5.15.14.19 and Dell ControlVault3 Plus prior to 6.2.36.47. A specially crafted WinBioControlUnit call can lead to memory corruption. An attacker can issue an api call to trigger this vulnerability. This vulnerability is triggered when submitting a `WinBioControlUnit` call to the StorageAdapter with the ControlCode 0 (`WBIO_USH_GET_TEMPLATE`) and with either and an invalid `ReceiveBuferSize` and/or an invalid `SendBufferSize`. | ||||
| CVE-2025-36462 | 2 Broadcom, Dell | 2 Bcm5820x, Controlvault3 | 2026-02-26 | 7.3 High |
| Multiple out-of-bounds read and write vulnerabilities exist in the ControlVault WBDI Driver Broadcom Storage Adapter functionality of Dell ControlVault3 prior to 5.15.14.19 and Dell ControlVault3 Plus prior to 6.2.36.47. A specially crafted WinBioControlUnit call can lead to memory corruption. An attacker can issue an api call to trigger this vulnerability. This vulnerability is triggered when submitting a `WinBioControlUnit` call to the StorageAdapter with the ControlCode 3 (`WBIO_USH_CREATE_CHALLENGE`) with an invalid `ReceiveBuferSize`. | ||||
| CVE-2025-36463 | 3 Broadcom, Dell, Microsoft | 3 Bcm5820x, Controlvault3, Windows | 2026-02-26 | 7.3 High |
| Multiple out-of-bounds read and write vulnerabilities exist in the ControlVault WBDI Driver Broadcom Storage Adapter functionality of Dell ControlVault3 prior to 5.15.14.19 and Dell ControlVault3 Plus prior to 6.2.36.47. A specially crafted WinBioControlUnit call can lead to memory corruption. An attacker can issue an api call to trigger this vulnerability. This vulnerability is triggered when submitting a `WinBioControlUnit` call to the StorageAdapter with the ControlCode 4 (`WBIO_USH_ADD_RECORD`) and with an invalid `SendBufferSize`. | ||||
| CVE-2025-31361 | 2 Broadcom, Dell | 2 Bcm5820x, Controlvault3 | 2026-02-26 | 8.7 High |
| A privilege escalation vulnerability exists in the ControlVault WBDI Driver WBIO_USH_ADD_RECORD functionality of Dell ControlVault3 prior to 5.15.14.19 and Dell ControlVault3 Plus prior to 6.2.36.47. A specially crafted WinBioControlUnit call can lead to privilege escalation. An attacker can issue an api call to trigger this vulnerability. | ||||
| CVE-2025-31649 | 2 Broadcom, Dell | 2 Bcm5820x, Controlvault3 | 2026-02-26 | 8.7 High |
| A hard-coded password vulnerability exists in the ControlVault WBDI Driver functionality of Dell ControlVault3 prior to 5.15.14.19 and Dell ControlVault3 Plus prior to 6.2.36.47. A specially crafted ControlVault API call can lead to execute priviledged operation. An attacker can issue an api call to trigger this vulnerability. | ||||
| CVE-2025-13918 | 2 Broadcom, Symantec | 2 Symantec Endpoint Protection, Endpoint Protection | 2026-02-26 | 6.7 Medium |
| Symantec Endpoint Protection, prior to 14.3 RU10 Patch 1, RU9 Patch 2, and RU8 Patch 3, may be susceptible to a Elevation of Privilege vulnerability, which is a type of issue whereby an attacker may attempt to compromise the software application to gain elevated access to resources that are normally protected from an application or user. | ||||
| CVE-2025-58382 | 2 Broadcom, Brocade | 2 Fabric Operating System, Fabric Os | 2026-02-26 | 7.2 High |
| A vulnerability in the secure configuration of authentication and management services in Brocade Fabric OS before Fabric OS 9.2.1c2 could allow an authenticated, remote attacker with administrative credentials to execute arbitrary commands as root using “supportsave”, “seccertmgmt”, “configupload” command. | ||||
| CVE-2025-58383 | 2 Broadcom, Brocade | 2 Fabric Operating System, Fabric Os | 2026-02-26 | 7.2 High |
| A vulnerability in Brocade Fabric OS versions before 9.2.1c2 could allow an administrator-level user to execute the bind command, to escalate privileges and bypass security controls allowing the execution of arbitrary commands. | ||||
| CVE-2026-0383 | 2 Broadcom, Brocade | 2 Fabric Operating System, Fabric Os | 2026-02-26 | 7.8 High |
| A vulnerability in Brocade Fabric OS could allow an authenticated, local attacker with privileges to access the Bash shell to access insecurely stored file contents including the history command. | ||||
| CVE-2025-9711 | 2 Broadcom, Brocade | 2 Fabric Operating System, Fabric Os | 2026-02-26 | 7.8 High |
| A vulnerability in Brocade Fabric OS before 9.2.1c3 could allow elevating the privileges of the local authenticated user to “root” using the export option of seccertmgmt and seccryptocfg commands. | ||||
| CVE-2024-5462 | 1 Broadcom | 1 Fabric Operating System | 2026-02-23 | 7.5 High |
| If Brocade Fabric OS before Fabric OS 9.2.0 configuration settings are not set to encrypt SNMP passwords, then the SNMP privsecret / authsecret fields can be exposed in plaintext. The plaintext passwords can be exposed in a configupload capture or a supportsave capture if encryption of passwords is not enabled. An attacker can use these passwords to fetch values of the supported OIDs via SNMPv3 queries. There are also a limited number of MIB objects that can be modified. | ||||