Filtered by CWE-78
Total 5721 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2023-30628 1 Kiwitcms 1 Kiwi Tcms 2025-02-12 8.8 High
Kiwi TCMS is an open source test management system. In kiwitcms/Kiwi v12.2 and prior and kiwitcms/enterprise v12.2 and prior, the `changelog.yml` workflow is vulnerable to command injection attacks because of using an untrusted `github.head_ref` field. The `github.head_ref` value is an attacker-controlled value. Assigning the value to `zzz";echo${IFS}"hello";#` can lead to command injection. Since the permission is not restricted, the attacker has a write-access to the repository. Commit 834c86dfd1b2492ccad7ebbfd6304bfec895fed2 of the kiwitcms/Kiwi repository and commit e39f7e156fdaf6fec09a15ea6f4e8fec8cdbf751 of the kiwitcms/enterprise repository contain a fix for this issue.
CVE-2023-25554 1 Schneider-electric 1 Struxureware Data Center Expert 2025-02-12 7.8 High
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that allows a local privilege escalation on the appliance when a maliciously crafted Operating System command is entered on the device. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-28726 1 Panasonic 2 Aiseg2, Aiseg2 Firmware 2025-02-12 7.5 High
Panasonic AiSEG2 versions 2.80F through 2.93A allows remote attackers to execute arbitrary OS commands.
CVE-2023-6321 2 Owletcare, Throughtek 5 Cam, Cam 2, Cam 2 Firmware and 2 more 2025-02-11 7.2 High
A command injection vulnerability exists in the IOCTL that manages OTA updates. A specially crafted command can lead to command execution as the root user. An attacker can make authenticated requests to trigger this vulnerability.
CVE-2023-26482 1 Nextcloud 1 Nextcloud Server 2025-02-11 9.1 Critical
Nextcloud server is an open source home cloud implementation. In affected versions a missing scope validation allowed users to create workflows which are designed to be only available for administrators. Some workflows are designed to be RCE by invoking defined scripts, in order to generate PDFs, invoking webhooks or running scripts on the server. Due to this combination depending on the available apps the issue can result in a RCE at the end. It is recommended that the Nextcloud Server is upgraded to 24.0.10 or 25.0.4. Users unable to upgrade should disable app `workflow_scripts` and `workflow_pdf_converter` as a mitigation.
CVE-2024-2448 2 Kemptechnologies, Progress 2 Loadmaster, Loadmaster 2025-02-11 8.4 High
An OS command injection vulnerability has been identified in LoadMaster.  An authenticated UI user with any permission settings may be able to inject commands into a UI component using a shell command resulting in OS command injection.
CVE-2024-45720 2 Apache, Microsoft 2 Subversion, Windows 2025-02-11 8.2 High
On Windows platforms, a "best fit" character encoding conversion of command line arguments to Subversion's executables (e.g., svn.exe, etc.) may lead to unexpected command line argument interpretation, including argument injection and execution of other programs, if a specially crafted command line argument string is processed. All versions of Subversion up to and including Subversion 1.14.3 are affected on Windows platforms only. Users are recommended to upgrade to version Subversion 1.14.4, which fixes this issue. Subversion is not affected on UNIX-like platforms.
CVE-2023-27917 1 Contec 38 Cps-mc341-a1-111, Cps-mc341-a1-111 Firmware, Cps-mc341-adsc1-111 and 35 more 2025-02-10 8.8 High
OS command injection vulnerability in CONPROSYS IoT Gateway products allows a remote authenticated attacker who can access Network Maintenance page to execute arbitrary OS commands with a root privilege. The affected products and versions are as follows: M2M Gateway with the firmware Ver.3.7.10 and earlier (CPS-MG341-ADSC1-111, CPS-MG341-ADSC1-931, CPS-MG341G-ADSC1-111, CPS-MG341G-ADSC1-930, and CPS-MG341G5-ADSC1-931), M2M Controller Integrated Type with firmware Ver.3.7.6 and earlier versions (CPS-MC341-ADSC1-111, CPS-MC341-ADSC1-931, CPS-MC341-ADSC2-111, CPS-MC341G-ADSC1-110, CPS-MC341Q-ADSC1-111, CPS-MC341-DS1-111, CPS-MC341-DS11-111, CPS-MC341-DS2-911, and CPS-MC341-A1-111), and M2M Controller Configurable Type with firmware Ver.3.8.8 and earlier versions (CPS-MCS341-DS1-111, CPS-MCS341-DS1-131, CPS-MCS341G-DS1-130, CPS-MCS341G5-DS1-130, and CPS-MCS341Q-DS1-131).
CVE-2024-53899 2 Redhat, Virtualenv 8 Enterprise Linux, Openshift Devspaces, Rhel Aus and 5 more 2025-02-10 8.4 High
virtualenv before 20.26.6 allows command injection through the activation scripts for a virtual environment. Magic template strings are not quoted correctly when replacing. NOTE: this is not the same as CVE-2024-9287.
CVE-2023-27216 1 Dlink 2 Dsl-3782, Dsl-3782 Firmware 2025-02-10 8.8 High
An issue found in D-Link DSL-3782 v.1.03 allows remote authenticated users to execute arbitrary code as root via the network settings page.
CVE-2023-27826 1 Seowonintech 2 Swc-5100w, Swc-5100w Firmware 2025-02-08 8.8 High
SeowonIntech SWC 5100W WIMAX Bootloader 1.18.19.0, HW 0.0.7.0, and FW 1.11.0.1, 1.9.9.4 are vulnerable to OS Command Injection. which allows attackers to take over the system with root privilege by abusing doSystem() function.
CVE-2023-6318 1 Lg 4 Oled48c1pub, Oled55a23la, Oled55cxpua and 1 more 2025-02-07 9.1 Critical
A command injection vulnerability exists in the processAnalyticsReport method from the com.webos.service.cloudupload service on webOS version 5 through 7. A series of specially crafted requests can lead to command execution as the root user. An attacker can make authenticated requests to trigger this vulnerability. Full versions and TV models affected: * webOS 5.5.0 - 04.50.51 running on OLED55CXPUA  * webOS 6.3.3-442 (kisscurl-kinglake) - 03.36.50 running on OLED48C1PUB  * webOS 7.3.1-43 (mullet-mebin) - 03.33.85 running on OLED55A23LA
CVE-2023-6319 1 Lg 5 Lg43um7000pla, Oled48c1pub, Oled55a23la and 2 more 2025-02-07 9.1 Critical
A command injection vulnerability exists in the getAudioMetadata method from the com.webos.service.attachedstoragemanager service on webOS version 4 through 7. A series of specially crafted requests can lead to command execution as the root user. An attacker can make authenticated requests to trigger this vulnerability. * webOS 4.9.7 - 5.30.40 running on LG43UM7000PLA  * webOS 5.5.0 - 04.50.51 running on OLED55CXPUA  * webOS 6.3.3-442 (kisscurl-kinglake) - 03.36.50 running on OLED48C1PUB  * webOS 7.3.1-43 (mullet-mebin) - 03.33.85 running on OLED55A23LA
CVE-2023-6320 1 Lg 3 Oled48c1pub, Oled55cxpua, Webos 2025-02-07 9.1 Critical
A command injection vulnerability exists in the com.webos.service.connectionmanager/tv/setVlanStaticAddress endpoint on webOS versions 5 and 6. A series of specially crafted requests can lead to command execution as the dbus user. An attacker can make authenticated requests to trigger this vulnerability. Full versions and TV models affected: * webOS 5.5.0 - 04.50.51 running on OLED55CXPUA  * webOS 6.3.3-442 (kisscurl-kinglake) - 03.36.50 running on OLED48C1PUB
CVE-2023-29805 1 Iodata 4 Wfs-sr03k, Wfs-sr03k Firmware, Wfs-sr03w and 1 more 2025-02-06 9.8 Critical
WFS-SR03 v1.0.3 was discovered to contain a command injection vulnerability via the pro_stor_canceltrans_handler_part_19 function.
CVE-2023-29804 1 Iodata 4 Wfs-sr03k, Wfs-sr03k Firmware, Wfs-sr03w and 1 more 2025-02-06 8.8 High
WFS-SR03 v1.0.3 was discovered to contain a command injection vulnerability via the sys_smb_pwdmod function.
CVE-2022-38841 1 Linksys 2 E8450, E8450 Firmware 2025-02-06 8.8 High
Linksys AX3200 1.1.00 is vulnerable to OS command injection by authenticated users via shell metacharacters to the diagnostics traceroute page.
CVE-2023-6260 1 Brivo 4 Acs100, Acs100 Firmware, Acs300 and 1 more 2025-02-05 9 Critical
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Brivo ACS100, ACS300 allows OS Command Injection, Bypassing Physical Security.This issue affects ACS100 (Network Adjacent Access), ACS300 (Physical Access): from 5.2.4 before 6.2.4.3.
CVE-2023-25555 1 Schneider-electric 1 Struxureware Data Center Expert 2025-02-05 5.6 Medium
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could allow a user that knows the credentials to execute unprivileged shell commands on the appliance over SSH. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-28983 1 Juniper 1 Junos Os Evolved 2025-02-05 8.8 High
An OS Command Injection vulnerability in gRPC Network Operations Interface (gNOI) server module of Juniper Networks Junos OS Evolved allows an authenticated, low privileged, network based attacker to inject shell commands and execute code. This issue affects Juniper Networks Junos OS Evolved 21.4 version 21.4R1-EVO and later versions prior to 22.1R1-EVO.