Filtered by vendor Tenda Subscriptions
Total 1855 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2025-70753 1 Tenda 2 Ax1806, Ax1806 Firmware 2026-01-16 7.5 High
Tenda AX-1806 v1.0.0.1 was discovered to contain a stack overflow in the security_5g parameter of the sub_4CA50 function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
CVE-2025-71024 1 Tenda 2 Ax3, Ax3 Firmware 2026-01-16 7.5 High
Tenda AX-3 v16.03.12.10_CN was discovered to contain a stack overflow in the serviceName2 parameter of the fromAdvSetMacMtuWan function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
CVE-2025-71025 1 Tenda 2 Ax3, Ax3 Firmware 2026-01-16 7.5 High
Tenda AX-3 v16.03.12.10_CN was discovered to contain a stack overflow in the cloneType2 parameter of the fromAdvSetMacMtuWan function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
CVE-2025-71027 1 Tenda 2 Ax3, Ax3 Firmware 2026-01-16 7.5 High
Tenda AX-3 v16.03.12.10_CN was discovered to contain a stack overflow in the wanMTU2 parameter of the fromAdvSetMacMtuWan function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
CVE-2025-71026 1 Tenda 2 Ax3, Ax3 Firmware 2026-01-16 7.5 High
Tenda AX-3 v16.03.12.10_CN was discovered to contain a stack overflow in the wanSpeed2 parameter of the fromAdvSetMacMtuWan function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
CVE-2025-67073 1 Tenda 4 Ac10, Ac10 Firmware, Ac10v4 and 1 more 2026-01-02 9.8 Critical
A Buffer overflow vulnerability in function fromAdvSetMacMtuWan of bin httpd in Tenda AC10V4.0 V16.03.10.20 allows remote attackers to cause denial of service and possibly code execution by sending a post request with a crafted payload (field `serviceName`) to /goform/AdvSetMacMtuWan.
CVE-2025-67074 1 Tenda 4 Ac10, Ac10 Firmware, Ac10v4 and 1 more 2026-01-02 6.5 Medium
A Buffer overflow vulnerability in function fromAdvSetMacMtuWan of bin httpd in Tenda AC10V4.0 V16.03.10.20 allows remote attackers to cause denial of service and possibly code execution by sending a post request with a crafted payload (field `serverName`) to /goform/AdvSetMacMtuWan.
CVE-2025-14994 1 Tenda 4 Fh1201, Fh1201 Firmware, Fh1206 and 1 more 2025-12-31 8.8 High
A flaw has been found in Tenda FH1201 and FH1206 1.2.0.14(408)/1.2.0.8(8155). This impacts the function strcat of the file /goform/webtypelibrary of the component HTTP Request Handler. This manipulation of the argument webSiteId causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been published and may be used.
CVE-2025-9806 1 Tenda 2 F1202, F1202 Firmware 2025-12-31 1.9 Low
A vulnerability was determined in Tenda F1202 1.2.0.9/1.2.0.14/1.2.0.20. Impacted is an unknown function of the file /etc_ro/shadow of the component Administrative Interface. This manipulation with the input Fireitup causes hard-coded credentials. The attack can only be executed locally. A high degree of complexity is needed for the attack. The exploitability is considered difficult. The exploit has been publicly disclosed and may be utilized.
CVE-2025-65804 1 Tenda 2 Ax3, Ax3 Firmware 2025-12-11 6.5 Medium
Tenda AX3 v16.03.12.11 contains a stack overflow in formSetIptv via the iptvType parameter, which can cause memory corruption and enable remote code execution (RCE).
CVE-2023-40894 1 Tenda 2 Ac8 Firmware, Ac8v4 2025-12-08 9.8 Critical
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetStaticRouteCfg.
CVE-2023-40895 1 Tenda 2 Ac8 Firmware, Ac8v4 2025-12-08 9.8 Critical
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetVirtualServerCfg.
CVE-2023-40893 1 Tenda 2 Ac8 Firmware, Ac8v4 2025-12-08 9.8 Critical
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter time at /goform/PowerSaveSet.
CVE-2023-40896 1 Tenda 2 Ac8 Firmware, Ac8v4 2025-12-08 9.8 Critical
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list and bindnum at /goform/SetIpMacBind.
CVE-2023-48194 1 Tenda 2 Ac8 Firmware, Ac8v4 2025-12-08 6.3 Medium
Vulnerability in Tenda AC8v4 .V16.03.34.09 due to sscanf and the last digit of s8 being overwritten with \x0. After executing set_client_qos, control over the gp register can be obtained.
CVE-2023-40900 1 Tenda 2 Ac8 Firmware, Ac8v4 2025-12-08 9.8 Critical
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetNetControlList.
CVE-2023-40897 1 Tenda 2 Ac8 Firmware, Ac8v4 2025-12-08 9.8 Critical
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter mac at /goform/GetParentControlInfo.
CVE-2023-39785 1 Tenda 3 Ac8 Firmware, Ac8v4, Ac8v4 Firmware 2025-12-08 7.5 High
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the list parameter in the set_qosMib_list function.
CVE-2023-40899 1 Tenda 3 Ac8, Ac8 Firmware, Ac8v4 2025-12-08 9.8 Critical
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at /goform/setMacFilterCfg.
CVE-2023-40898 1 Tenda 3 Ac8, Ac8 Firmware, Ac8v4 2025-12-08 9.8 Critical
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter timeZone at /goform/SetSysTimeCfg.