Total
1829 CVE
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-64766 | 2 Nixos, Onlyoffice | 2 Nixos, Onlyoffice | 2026-04-15 | 5.3 Medium |
| NixOS's Onlyoffice is a software suite that offers online and offline tools for document editing, collaboration, and management. In versions from 22.11 to before 25.05 and versions before Unstable 25.11, a hard-coded secret was used in the NixOS module for the OnlyOffice document server to protect its file cache. An attacker with knowledge of an existing revision ID could use this secret to obtain a document. In practice, an arbitrary revision ID should be hard to obtain. The primary impact is likely the access to known documents from users with expired access. This issue was resolved in NixOS unstable version 25.11 and version 25.05. | ||||
| CVE-2025-37103 | 2026-04-15 | 9.8 Critical | ||
| Hard-coded login credentials were found in HPE Networking Instant On Access Points, allowing anyone with knowledge of it to bypass normal device authentication. Successful exploitation could allow a remote attacker to gain administrative access to the system. | ||||
| CVE-2024-10025 | 1 Sick | 52 Clv620 Firmware, Clv621 Firmware, Clv622 Firmware and 49 more | 2026-04-15 | 9.1 Critical |
| A vulnerability in the .sdd file allows an attacker to read default passwords stored in plain text within the code. By exploiting these plaintext credentials, an attacker can log into affected SICK products as an “Authorized Client” if the customer has not changed the default password. | ||||
| CVE-2023-6198 | 2026-04-15 | 9.3 Critical | ||
| Use of Hard-coded Credentials vulnerability in Baicells Snap Router BaiCE_BMI on EP3011 (User Passwords modules) allows unauthorized access to the device. | ||||
| CVE-2025-55047 | 2026-04-15 | 8.4 High | ||
| CWE-798 Use of Hard-coded Credentials | ||||
| CVE-2025-43982 | 2026-04-15 | 9.8 Critical | ||
| Shenzhen Tuoshi NR500-EA RG500UEAABxCOMSLICv3.4.2731.16.43 devices enable the SSH service by default. There is a hidden hard-coded root account that cannot be disabled in the GUI. | ||||
| CVE-2024-11630 | 1 E-lins | 9 H685, H685f, H700 and 6 more | 2026-04-15 | 7.3 High |
| A vulnerability has been found in E-Lins H685, H685f, H700, H720, H750, H820, H820Q, H820Q0 and H900 up to 3.2 and classified as critical. This vulnerability affects unknown code of the component OEM Backend. The manipulation leads to hard-coded credentials. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. It is recommended to change the configuration settings. The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2025-14115 | 1 Ibm | 1 Sterling Connectdirect For Unix Container | 2026-04-15 | 8.4 High |
| IBM Sterling Connect:Direct for UNIX Container 6.3.0.0 through 6.3.0.6 Interim Fix 016, and 6.4.0.0 through 6.4.0.3 Interim Fix 019 IBM® Sterling Connect:Direct for UNIX contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. | ||||
| CVE-2025-5379 | 2026-04-15 | 4.3 Medium | ||
| A vulnerability classified as critical was found in NuCom NC-WR744G 8.5.5 Build 20200530.307. This vulnerability affects unknown code of the component Console Application. The manipulation of the argument CMCCAdmin/useradmin/CUAdmin leads to hard-coded credentials. The attack can be initiated remotely. The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2025-51606 | 2026-04-15 | 8.8 High | ||
| hippo4j 1.0.0 to 1.5.0, uses a hard-coded secret key in its JWT (JSON Web Token) creation. This allows attackers with access to the source code or compiled binary to forge valid access tokens and impersonate any user, including privileged ones such as "admin". The vulnerability poses a critical security risk in systems where authentication and authorization rely on the integrity of JWTs. | ||||
| CVE-2018-25126 | 1 Tvt | 1 Nvms-9000 Firmware | 2026-04-15 | N/A |
| Shenzhen TVT Digital Technology Co., Ltd. NVMS-9000 firmware (used by many white-labeled DVR/NVR/IPC products) contains hardcoded API credentials and an OS command injection flaw in its configuration services. The web/API interface accepts HTTP/XML requests authenticated with a fixed vendor credential string and passes user-controlled fields into shell execution contexts without proper argument sanitization. An unauthenticated remote attacker can leverage the hard-coded credential to access endpoints such as /editBlackAndWhiteList and inject shell metacharacters inside XML parameters, resulting in arbitrary command execution as root. The same vulnerable backend is also reachable in some models through a proprietary TCP service on port 4567 that accepts a magic GUID preface and base64-encoded XML, enabling the same command injection sink. Firmware releases from mid-February 2018 and later are reported to have addressed this issue. Exploitation evidence was observed by the Shadowserver Foundation on 2025-01-28 UTC. | ||||
| CVE-2024-53614 | 2026-04-15 | 6.5 Medium | ||
| A hardcoded decryption key in Thinkware Cloud APK v4.3.46 allows attackers to access sensitive data and execute arbitrary commands with elevated privileges. | ||||
| CVE-2024-32988 | 2026-04-15 | 7.5 High | ||
| 'OfferBox' App for Android versions 2.0.0 to 2.3.17 and 'OfferBox' App for iOS versions 2.1.7 to 2.6.14 use a hard-coded secret key for JWT. Secret key for JWT may be retrieved if the application binary is reverse-engineered. | ||||
| CVE-2025-4569 | 1 Asus | 1 Myasus | 2026-04-15 | N/A |
| An insecure sensitive key storage issue was found in MyASUS. potentially allowing unauthorized actor to obtain a token that could be used to communicate with certain services. Refer to the 'Security Update for for MyASUS' section on the ASUS Security Advisory for more information. | ||||
| CVE-2024-39208 | 1 Luciapplucky | 1 Luci-app-lucky | 2026-04-15 | 9.8 Critical |
| luci-app-lucky v2.8.3 was discovered to contain hardcoded credentials. | ||||
| CVE-2025-7342 | 1 Kubernetes | 1 Image Builder | 2026-04-15 | 7.5 High |
| A security issue was discovered in the Kubernetes Image Builder where default credentials are enabled during the Windows image build process when using the Nutanix or VMware OVA providers. These credentials, which allow root access, are disabled at the conclusion of the build. Kubernetes clusters are only affected if their nodes use VM images created via the Image Builder project and the vulnerability was exploited during the build process, which requires an attacker to access the build VM and modify the image while the build is in progress. | ||||
| CVE-2025-57577 | 1 H3c | 1 R365v300r004 | 2026-04-15 | 8 High |
| An issue in H3C Device R365V300R004 allows a remote attacker to execute arbitrary code via the default password. NOTE: the Supplier's position is that their "product lines enforce or clearly prompt users to change any initial credentials upon first use. At most, this would be a case of misconfiguration if an administrator deliberately ignored the prompts, which is outside the scope of CVE definitions." | ||||
| CVE-2025-57601 | 1 Aikaan | 1 Cloud Controller | 2026-04-15 | 9.8 Critical |
| AiKaan Cloud Controller uses a single hardcoded SSH private key and the username `proxyuser` for remote terminal access to all managed IoT/edge devices. When an administrator initiates "Open Remote Terminal" from the AiKaan dashboard, the controller sends this same static private key to the target device. The device then uses it to establish a reverse SSH tunnel to a remote access server, enabling browser-based SSH access for the administrator. Because the same `proxyuser` account and SSH key are reused across all customer environments: - An attacker who obtains the key (e.g., by intercepting it in transit, extracting it from the remote access server, or from a compromised admin account) can impersonate any managed device. - They can establish unauthorized reverse SSH tunnels and interact with devices without the owner's consent. This is a design flaw in the authentication model: compromise of a single key compromises the trust boundary between the controller and devices. | ||||
| CVE-2024-2161 | 2026-04-15 | 9.8 Critical | ||
| Use of Hard-coded Credentials in Kiloview NDI allows un-authenticated users to bypass authenticationThis issue affects Kiloview NDI N3, N3-s, N4, N20, N30, N40 and was fixed in Firmware version 2.02.0227 . | ||||
| CVE-2025-57602 | 1 Aikaan | 1 Iot Management Platform | 2026-04-15 | 9.8 Critical |
| Insufficient hardening of the proxyuser account in the AiKaan IoT management platform, combined with the use of a shared, hardcoded SSH private key, allows remote attackers to authenticate to the cloud controller, gain interactive shell access, and pivot into other connected IoT devices. This can lead to remote code execution, information disclosure, and privilege escalation across customer environments. | ||||