| CVE-2026-61409 | 1 Dell | 2 Secure Connect Gateway Appliance, Secure Connect Gateway Application | 2026-09-08 | 7.3 High |
| Dell Secure Connect Gateway (SCG) 5.0 Application, versions prior to 5.36.00.00, contains an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to remote execution. | ||||
| CVE-2026-19843 | 1 Redhat | 6 Directory Server, Directory Server E2s, Directory Server E4s and 3 more | 2026-09-08 | 8.4 High |
| A flaw was found in 389-ds-base. The Cockpit 389 Console's LDAP editor constructs an ldapsearch command by embedding an LDAP entry's distinguished name (DN) into a shell command string without proper escaping. An LDAP user with delegated privileges to create or rename directory entries could craft a malicious DN containing shell metacharacters. When a Cockpit administrator subsequently views the entry in the 389 Console, the embedded shell command executes with root privileges on the directory server host. | ||||
| CVE-2026-76561 | 1 Redhat | 2 Certificate System, Enterprise Linux | 2026-09-08 | 7.2 High |
| A flaw was found in Dogtag PKI, as used by FreeIPA's certificate authority component. The certificate profile import functionality does not fully validate uploaded profile content beyond the profile ID. An authenticated user with CA Administrator privileges can exploit Dogtag's ExternalProcessConstraint mechanism to execute arbitrary commands with attacker-controlled environment variables, achieving code execution as the pkiuser account. | ||||
| CVE-2026-61517 | 1 Netis-systems | 1 Nx10 | 2026-09-08 | 7.2 High |
| Netis NX10 firmware V4.0.1.5808 and V3.0.0.4142 contain an OS command injection vulnerability in the ping diagnostic handler that allows authenticated administrators to execute arbitrary shell commands as root by injecting into the IpAddr parameter. The parameter is interpolated directly into a shell command executed through system() with an incomplete denylist that only blocks spaces, pipes, semicolons, and ampersands, leaving command substitution and alternate field separator expansion available for exploitation. | ||||
| CVE-2026-80127 | 1 Dell | 2 Secure Connect Gateway Appliance, Secure Connect Gateway Application | 2026-09-08 | 7.2 High |
| Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to elevation of privileges. | ||||
| CVE-2025-34115 | 1 Op5 | 1 Monitor | 2026-09-08 | N/A |
| An authenticated command injection vulnerability exists in OP5 Monitor through version 7.1.9 via the 'cmd_str' parameter in the command_test.php endpoint. A user with access to the web interface can exploit the 'Test this command' feature to execute arbitrary shell commands as the unprivileged web application user. The vulnerability resides in the configuration section of the application and requires valid login credentials with access to the command testing functionality. This issue is fixed in version 7.2.0. | ||||
| CVE-2026-78630 | 2026-09-08 | 6.7 Medium | ||
| The Okta Access Gateway does not neutralize shell metacharacters in SNMP configuration values before a privileged script uses them to construct OS commands. An authenticated local user with access to the management interface can supply crafted values, resulting in the execution of arbitrary OS commands with root privileges. | ||||
| CVE-2026-18073 | 1 Ibm | 1 I | 2026-09-08 | 4.4 Medium |
| IBM i 7.6, 7.5, 7.4, and 7.3 could allow a local authenticated attacker to inject parameters into a CL command due to improper neutralization of special elements. | ||||
| CVE-2025-67038 | 1 Lantronix | 67 E213f102s, E213f102s Firmware, E214f002s and 64 more | 2026-09-08 | 9.8 Critical |
| An issue was discovered in Lantronix EDS5000 2.1.0.0R3. The HTTP RPC module executes a shell command to write logs when user's authentication fails. The username is directly concatenated with the command without any sanitization. This allow attackers to inject arbitrary OS commands into the username parameter. Injected commands are executed with root privileges. | ||||
| CVE-2026-86167 | 1 Tenda | 2 Hg10, Hg10 Firmware | 2026-09-08 | 9.9 Critical |
| A vulnerability was identified in Tenda HG10 300001138. Impacted is the function formgponConf of the file /boaform/admin/formgponConf of the component Boa. The manipulation of the argument fmgpon_loid leads to os command injection. Remote exploitation of the attack is possible. The exploit is publicly available and might be used. | ||||
| CVE-2026-86148 | 1 Tenda | 2 Cp3, Cp3 Firmware | 2026-09-08 | 9.1 Critical |
| A security flaw has been discovered in Tenda CP3 27.5.57.101. This vulnerability affects the function SystemAsh of the file Apis/system.c of the component Kylin. The manipulation of the argument AlarmVoiceURL results in os command injection. It is possible to launch the attack remotely. | ||||
| CVE-2026-86733 | 2 Grokability, Snipeitapp | 2 Snipe-it, Snipe-it | 2026-09-08 | 7.2 High |
| Snipe-IT before 8.7.0 streams the SQL entry from an uploaded backup archive directly into the MySQL/MariaDB command-line client (`mysql`) without the --binary-mode flag, so the client interprets lines beginning with backslash commands such as `\!` as local shell commands. An authenticated superadministrator who uploads a crafted ZIP backup (POST /admin/backups/upload) and triggers a restore (POST /admin/backups/restore/{filename}) without the optional `clean` sanitizer parameter — which is not applied by default because DB_SANITIZE_BY_DEFAULT is false — can execute arbitrary OS commands as the web application's operating-system user, exposing application secrets (including database credentials and APP_KEY) and allowing modification of application-writable files and data. Version 8.7.0 adds the --binary-mode flag to the client invocation. | ||||
| CVE-2026-16826 | 1 Ibm | 1 I | 2026-09-08 | 5.3 Medium |
| IBM i 7.6, 7.5, 7.4, and 7.3 could allow a local attacker to execute arbitrary commands due to improper neutralization of special elements used in an OS command. | ||||
| CVE-2026-53932 | 1 Stefanzweifel | 1 Laravel-backup-restore | 2026-09-08 | 8 High |
| laravel-backup-restore restores database backups made with spatie/laravel-backup. Prior to version 1.9.4, a crafted backup archive can trigger OS command injection during database restore. This issue has been patched in version 1.9.4. | ||||
| CVE-2026-79423 | 1 Seacms | 1 Seacms | 2026-09-08 | 8.8 High |
| An authenticated remote code execution (RCE) vulnerability in the admin_config.php component of seacms v13.6 allows attackers to execute arbitrary code via a crafted POST request. | ||||
| CVE-2026-84256 | 1 Openvpn | 1 Openvpn | 2026-09-08 | 8.8 High |
| An argument parsing issue in OpenVPN 2.1_rc10 through 2.6.22 and 2.7_alpha1 through 2.7.6 on Windows allows remote authenticated users to execute arbitrary commands via a crafted certificate subject | ||||
| CVE-2026-86540 | 1 Knowns-dev | 1 Knowns | 2026-09-08 | 7.8 High |
| knowns versions before 0.30.0 fail to validate the settings.lsp.languages binary field in project configuration files, allowing attackers to execute arbitrary binaries by crafting a malicious .knowns/config.json file. When a repository with a crafted configuration is opened, the unvalidated binary path is executed twice under the user's account without any verification. | ||||
| CVE-2026-71376 | 1 Hitachi | 1 Cosminexus Component Container | 2026-09-08 | 9.8 Critical |
| OS command injection vulnerability in Cosminexus Component Container. This issue affects Cosminexus Component Container: from 11-70-01 before 11-70-03, from 11-60 before 11-60-03, from 11-50 through 11-50-03, from 11-40 through 11-40-03, from 11-30 through 11-30-08, from 11-20 before 11-20-10, from 11-10 through 11-10-11, from 11-00 before 11-00-13, from 09-87 before 09-87-10, from 09-80 before 09-80-05, from 09-70 before 09-70-28, from 09-50 through 09-50-22, and from 09-00 through 09-00-18. | ||||
| CVE-2025-40582 | 1 Siemens | 2 Scalance Lpe9403, Scalance Lpe9403 Firmware | 2026-09-08 | 7.8 High |
| A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V2.1 HF0 with SINEMA Remote Connect Edge Client installed). Affected devices do not properly sanitize configuration parameters. This could allow a non-privileged local attacker to execute root commands on the device. | ||||
| CVE-2026-86299 | 1 Linksys | 2 Re7000, Re7000 Firmware | 2026-09-07 | 9.9 Critical |
| A vulnerability was detected in Linksys RE7000 2.0.15. This affects the function platform_event_pingTest of the file /cgi-bin/json.cgi?PingTest of the component PingTest Handler. The manipulation of the argument pingTestIp/pingTestPktSize/pingTestTimes results in os command injection. The attack can be launched remotely. The exploit is now public and may be used. | ||||