Filtered by vendor Juniper
Subscriptions
Total
1111 CVE
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2017-2327 | 1 Juniper | 1 Northstar Controller | 2025-04-20 | N/A |
| A denial of service vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pack 1 may allow an authenticated malicious user to consume large amounts of system resources leading to a cascading denial of services. | ||||
| CVE-2017-10603 | 1 Juniper | 1 Junos | 2025-04-20 | N/A |
| An XML injection vulnerability in Junos OS CLI can allow a locally authenticated user to elevate privileges and run arbitrary commands as the root user. This issue was found during internal product security testing. Affected releases are Juniper Networks Junos OS 15.1X53 prior to 15.1X53-D47, 15.1 prior to 15.1R3. Junos versions prior to 15.1 are not affected. No other Juniper Networks products or platforms are affected by this issue. | ||||
| CVE-2017-2307 | 1 Juniper | 1 Junos Space | 2025-04-20 | N/A |
| A reflected cross site scripting vulnerability in the administrative interface of Juniper Networks Junos Space versions prior to 16.1R1 may allow remote attackers to steal sensitive information or perform certain administrative actions on Junos Space. | ||||
| CVE-2017-2344 | 1 Juniper | 1 Junos | 2025-04-20 | N/A |
| A routine within an internal Junos OS sockets library is vulnerable to a buffer overflow. Malicious exploitation of this issue may lead to a denial of service (kernel panic) or be leveraged as a privilege escalation through local code execution. The routines are only accessible via programs running on the device itself, and veriexec restricts arbitrary programs from running on Junos OS. There are no known exploit vectors utilizing signed binaries shipped with Junos OS itself. Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D67; 12.3X48 prior to 12.3X48-D51, 12.3X48-D55; 13.3 prior to 13.3R10-S2; 14.1 prior to 14.1R2-S10, 14.1R8-S4, 14.1R9; 14.1X50 prior to 14.1X50-D185; 14.1X53 prior to 14.1X53-D122, 14.1X53-D45, 14.1X53-D50; 14.2 prior to 14.2R4-S9, 14.2R7-S7, 14.2R8; 15.1 prior to 15.1F2-S18, 15.1F6-S7, 15.1R4-S8, 15.1R5-S5, 15.1R6-S1, 15.1R7; 15.1X49 prior to 15.1X49-D100; 15.1X53 prior to 15.1X53-D231, 15.1X53-D47, 15.1X53-D48, 15.1X53-D57, 15.1X53-D64, 15.1X53-D70; 16.1 prior to 16.1R3-S4, 16.1R4-S3, 16.1R4-S4, 16.1R5; 16.2 prior to 16.2R2; 17.1 prior to 17.1R1-S3, 17.1R2; 17.2 prior to 17.2R1-S1, 17.2R2; 17.2X75 prior to 17.2X75-D30. No other Juniper Networks products or platforms are affected by this issue. | ||||
| CVE-2017-2341 | 1 Juniper | 13 Acx5000, Ex4600, Junos and 10 more | 2025-04-20 | N/A |
| An insufficient authentication vulnerability on platforms where Junos OS instances are run in a virtualized environment, may allow unprivileged users on the Junos OS instance to gain access to the host operating environment, and thus escalate privileges. Affected releases are Juniper Networks Junos OS 14.1X53 prior to 14.1X53-D40 on QFX5110, QFX5200, QFX10002, QFX10008, QFX10016, EX4600 and NFX250; 15.1 prior to 15.1R5 on EX4600; 15.1X49 prior to 15.1X49-D70 on vSRX, SRX1500, SRX4100, SRX4200; 16.1 prior to 16.1R2 on EX4600, ACX5000 series. This issue does not affect vMX. No other Juniper Networks products or platforms are affected by this issue. | ||||
| CVE-2017-10619 | 1 Juniper | 7 Junos, Srx1400, Srx3400 and 4 more | 2025-04-20 | N/A |
| When Express Path (formerly known as service offloading) is configured on Juniper Networks SRX1400, SRX3400, SRX3600, SRX5400, SRX5600, SRX5800 in high availability cluster configuration mode, certain multicast packets might cause the flowd process to crash, halting or interrupting traffic from flowing through the device and triggering RG1+ (data-plane) fail-over to the secondary node. Repeated crashes of the flowd process may constitute an extended denial of service condition. This service is not enabled by default and is only supported in high-end SRX platforms. Affected releases are Juniper Networks Junos OS 12.3X48 prior to 12.3X48-D45, 15.1X49 prior to 15.1X49-D80 on SRX1400, SRX3400, SRX3600, SRX5400, SRX5600, SRX5800. | ||||
| CVE-2017-2317 | 1 Juniper | 1 Northstar Controller | 2025-04-20 | N/A |
| A denial of service vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pack 1 may allow an unauthenticated, unprivileged, network-based attacker to cause denials of services to underlying database tables leading to potential information disclosure, modification of system states, and partial to full denial of services relying upon data modified by an attacker. | ||||
| CVE-2017-2322 | 1 Juniper | 1 Northstar Controller | 2025-04-20 | N/A |
| A denial of service vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pack 1, may allow an authenticated user to cause widespread denials of service to system services by consuming TCP and UDP ports which are normally reserved for other system services. | ||||
| CVE-2017-10610 | 1 Juniper | 2 Junos, Srx Series | 2025-04-20 | N/A |
| On SRX Series devices, a crafted ICMP packet embedded within a NAT64 IPv6 to IPv4 tunnel may cause the flowd process to crash. Repeated crashes of the flowd process constitutes an extended denial of service condition for the SRX Series device. This issue only occurs if NAT64 is configured. Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D71, 12.3X48 prior to 12.3X48-D55, 15.1X49 prior to 15.1X49-D100 on SRX Series. No other Juniper Networks products or platforms are affected by this issue. | ||||
| CVE-2017-2332 | 1 Juniper | 1 Northstar Controller | 2025-04-20 | N/A |
| An insufficient authentication vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pack 1 may allow a malicious, network based, unauthenticated attacker to perform privileged actions to gain complete control over the environment. | ||||
| CVE-2017-2312 | 1 Juniper | 1 Junos | 2025-04-20 | N/A |
| On Juniper Networks devices running Junos OS affected versions and with LDP enabled, a specific LDP packet destined to the RE (Routing Engine) will consume a small amount of the memory allocated for the rpd (routing protocol daemon) process. Over time, repeatedly receiving this type of LDP packet(s) will cause the memory to exhaust and the rpd process to crash and restart. It is not possible to free up the memory that has been consumed without restarting the rpd process. This issue affects Junos OS based devices with either IPv4 or IPv6 LDP enabled via the [protocols ldp] configuration (the native IPv6 support for LDP is available in Junos OS 16.1 and higher). The interface on which the packet arrives needs to have LDP enabled. The affected Junos versions are: 13.3 prior to 13.3R10; 14.1 prior to 14.1R8; 14.2 prior to 14.2R7-S6 or 14.2R8; 15.1 prior to 15.1F2-S14, 15.1F6-S4, 15.1F7, 15.1R4-S7, 15.1R5; 15.1X49 before 15.1X49-D70; 15.1X53 before 15.1X53-D230, 15.1X53-D63, 15.1X53-D70; 16.1 before 16.1R2. 16.2R1 and all subsequent releases have a resolution for this vulnerability. | ||||
| CVE-2017-2313 | 1 Juniper | 1 Junos | 2025-04-20 | N/A |
| Juniper Networks devices running affected Junos OS versions may be impacted by the receipt of a crafted BGP UPDATE which can lead to an rpd (routing process daemon) crash and restart. Repeated crashes of the rpd daemon can result in an extended denial of service condition. The affected Junos OS versions are: 15.1 prior to 15.1F2-S15, 15.1F5-S7, 15.1F6-S5, 15.1F7, 15.1R4-S7, 15.1R5-S2, 15.1R6; 15.1X49 prior to 15.1X49-D78, 15.1X49-D80; 15.1X53 prior to 15.1X53-D230, 15.1X53-D63, 15.1X53-D70; 16.1 prior to 16.1R3-S3, 16.1R4; 16.2 prior to 16.2R1-S3, 16.2R2; Releases prior to Junos OS 15.1 are unaffected by this vulnerability. 17.1R1, 17.2R1, and all subsequent releases have a resolution for this vulnerability. | ||||
| CVE-2017-2305 | 1 Juniper | 1 Junos Space | 2025-04-20 | N/A |
| On Juniper Networks Junos Space versions prior to 16.1R1, due to an insufficient authorization check, readonly users on the Junos Space administrative web interface can create privileged users, allowing privilege escalation. | ||||
| CVE-2016-4925 | 1 Juniper | 1 Junose | 2025-04-20 | N/A |
| Receipt of a specifically malformed IPv6 packet processed by the router may trigger a line card reset: processor exception 0x68616c74 (halt) in task: scheduler. The line card will reboot and recover without user interaction. However, additional specifically malformed packets may cause follow-on line card resets and lead to an extended service outage. This issue only affects E Series routers with IPv6 licensed and enabled. Routers not configured to process IPv6 traffic are unaffected by this vulnerability. Juniper SIRT is not aware of any malicious exploitation of this vulnerability. No other Juniper Networks products or platforms are affected by this issue. | ||||
| CVE-2017-10620 | 1 Juniper | 21 Junos, Srx100, Srx110 and 18 more | 2025-04-20 | N/A |
| Juniper Networks Junos OS on SRX series devices do not verify the HTTPS server certificate before downloading anti-virus updates. This may allow a man-in-the-middle attacker to inject bogus signatures to cause service disruptions or make the device not detect certain types of attacks. Affected Junos OS releases are: 12.1X46 prior to 12.1X46-D71; 12.3X48 prior to 12.3X48-D55; 15.1X49 prior to 15.1X49-D110; | ||||
| CVE-2016-7103 | 7 Debian, Fedoraproject, Jqueryui and 4 more | 13 Debian Linux, Fedora, Jquery Ui and 10 more | 2025-04-20 | 6.1 Medium |
| Cross-site scripting (XSS) vulnerability in jQuery UI before 1.12.0 might allow remote attackers to inject arbitrary web script or HTML via the closeText parameter of the dialog function. | ||||
| CVE-2017-10616 | 1 Juniper | 1 Contrail | 2025-04-20 | 5.3 Medium |
| The ifmap service that comes bundled with Juniper Networks Contrail releases uses hard coded credentials. Affected releases are Contrail releases 2.2 prior to 2.21.4; 3.0 prior to 3.0.3.4; 3.1 prior to 3.1.4.0; 3.2 prior to 3.2.5.0. CVE-2017-10616 and CVE-2017-10617 can be chained together and have a combined CVSSv3 score of 5.8 (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N). | ||||
| CVE-2017-2315 | 1 Juniper | 1 Junos | 2025-04-20 | N/A |
| On Juniper Networks EX Series Ethernet Switches running affected Junos OS versions, a vulnerability in IPv6 processing has been discovered that may allow a specially crafted IPv6 Neighbor Discovery (ND) packet destined to an EX Series Ethernet Switch to cause a slow memory leak. A malicious network-based packet flood of these crafted IPv6 NDP packets may eventually lead to resource exhaustion and a denial of service. The affected Junos OS versions are: 12.3 prior to 12.3R12-S4, 12.3R13; 13.3 prior to 13.3R10; 14.1 prior to 14.1R8-S3, 14.1R9; 14.1X53 prior ro 14.1X53-D12, 14.1X53-D40; 14.1X55 prior to 14.1X55-D35; 14.2 prior to 14.2R6-S4, 14.2R7-S6, 14.2R8; 15.1 prior to 15.1R5; 16.1 before 16.1R3; 16.2 before 16.2R1-S3, 16.2R2. 17.1R1 and all subsequent releases have a resolution for this vulnerability. | ||||
| CVE-2017-2300 | 1 Juniper | 1 Junos | 2025-04-20 | N/A |
| On Juniper Networks SRX Series Services Gateways chassis clusters running Junos OS 12.1X46 prior to 12.1X46-D65, 12.3X48 prior to 12.3X48-D40, 12.3X48 prior to 12.3X48-D60, flowd daemon on the primary node of an SRX Series chassis cluster may crash and restart when attempting to synchronize a multicast session created via crafted multicast packets. | ||||
| CVE-2016-4930 | 1 Juniper | 1 Junos Space | 2025-04-20 | N/A |
| Cross-site scripting (XSS) vulnerability in Junos Space before 15.2R2 allows remote attackers to steal sensitive information or perform certain administrative actions. | ||||