CVE-2026-5882 4 Apple, Google, Linux and 1 more 4 Macos, Chrome, Linux Kernel and 1 more 2026-04-15 4.3 Medium
Incorrect security UI in Fullscreen in Google Chrome prior to 147.0.7727.55 allowed a remote attacker to perform UI spoofing via a crafted HTML page. (Chromium security severity: Medium)
CVE-2026-5892 4 Apple, Google, Linux and 1 more 4 Macos, Chrome, Linux Kernel and 1 more 2026-04-15 6.6 Medium
Insufficient policy enforcement in PWAs in Google Chrome prior to 147.0.7727.55 allowed a remote attacker who had compromised the renderer process to install a PWA without user consent via a crafted HTML page. (Chromium security severity: Medium)
CVE-2026-5894 4 Apple, Google, Linux and 1 more 4 Macos, Chrome, Linux Kernel and 1 more 2026-04-15 4.3 Medium
Inappropriate implementation in PDF in Google Chrome prior to 147.0.7727.55 allowed a remote attacker to bypass navigation restrictions via a crafted HTML page. (Chromium security severity: Low)
CVE-2026-5896 4 Apple, Google, Linux and 1 more 4 Macos, Chrome, Linux Kernel and 1 more 2026-04-15 6.1 Medium
Policy bypass in Audio in Google Chrome prior to 147.0.7727.55 allowed a remote attacker who convinced a user to engage in specific UI gestures to bypass sandbox download restrictions via a crafted HTML page. (Chromium security severity: Low)
CVE-2026-5907 4 Apple, Google, Linux and 1 more 4 Macos, Chrome, Linux Kernel and 1 more 2026-04-15 8.1 High
Insufficient data validation in Media in Google Chrome prior to 147.0.7727.55 allowed a remote attacker to perform an out of bounds memory read via a crafted video file. (Chromium security severity: Low)
CVE-2025-5191 2 Microsoft, Moxa 5 Windows, Drp-a100, Drp-c100 and 2 more 2026-04-15 N/A
An Unquoted Search Path vulnerability has been identified in the utility for Moxa’s industrial computers (Windows). Due to the unquoted path configuration in the SerialInterfaceService.exe utility, a local attacker with limited privileges could place a malicious executable in a higher-priority directory within the search path. When the Serial Interface service starts, the malicious executable could be run with SYSTEM privileges. Successful exploitation could allow privilege escalation or enable an attacker to maintain persistence on the affected system. While successful exploitation can severely impact the confidentiality, integrity, and availability of the affected device itself, there is no loss of confidentiality, integrity, or availability within any subsequent systems.
CVE-2017-20201 2 Microsoft, Piriform 2 Windows, Ccleaner 2026-04-15 N/A
CCleaner v5.33.6162 and CCleaner Cloud v1.07.3191 (32-bit builds) contained a malicious pre-entry-point loader that diverts execution from __scrt_common_main_seh into a custom loader. That loader decodes an embedded blob into shellcode, allocates executable heap memory, resolves Windows API functions at runtime, and transfers execution to an in-memory payload. The payload performs anti-analysis checks, gathers host telemetry, encodes the data with a two-stage obfuscation, and attempts HTTPS exfiltration to hard-coded C2 servers or month-based DGA domains. Potential impacts include remote data collection and exfiltration, stealthy in-memory execution and persistence, and potential lateral movement. CCleaner was developed by Piriform, which was acquired by Avast in July 2017; Avast later merged with NortonLifeLock to form the parent company now known as Gen Digital. According to vendor advisories, the compromised CCleaner build was released on August 15, 2017 and remediated on September 12, 2017 with v5.34; the compromised CCleaner Cloud build was released on August 24, 2017 and remediated on September 15, 2017 with v1.07.3214.
CVE-2025-27233 2 Microsoft, Zabbix 4 Windows, Zabbix, Zabbix-agent and 1 more 2026-04-15 N/A
Zabbix Agent 2 smartctl plugin does not properly sanitize smart.disk.get parameters, allowing an attacker to inject unexpected arguments into the smartctl command. This can be used to leak the NTLMv2 hash from a Windows system.
CVE-2025-11535 2 Microsoft, Mongodb 3 Windows, Connector For Bi, Mongodb 2026-04-15 N/A
MongoDB Connector for BI installation via MSI on Windows leaves ACLs unset on custom install directories allows Privilege Escalation.This issue affects MongoDB Connector for BI: from 2.0.0 through 2.14.24.
CVE-2025-37735 2 Elastic, Microsoft 2 Defend, Windows 2026-04-15 7 High
Improper preservation of permissions in Elastic Defend on Windows hosts can lead to arbitrary files on the system being deleted by the Defend service running as SYSTEM. In some cases, this could result in local privilege escalation.
CVE-2025-36854 1 Microsoft 1 .net 2026-04-15 8.1 High
A vulnerability ( CVE-2024-38229 https://www.cve.org/CVERecord ) exists in EOL ASP.NET when closing an HTTP/3 stream while application code is writing to the response body, a race condition may lead to use-after-free, resulting in Remote Code Execution. Per CWE-416: Use After Free https://cwe.mitre.org/data/definitions/416.html , Use After Free is when a product reuses or references memory after it has been freed. At some point afterward, the memory may be allocated again and saved in another pointer, while the original pointer references a location somewhere within the new allocation. Any operations using the original pointer are no longer valid because the memory "belongs" to the code that operates on the new pointer. This issue affects EOL ASP.NET 6.0.0 <= 6.0.36 as represented in this CVE, as well as 8.0.0 <= 8.0.8, 9.0.0-preview.1.24081.5 <= 9.0.0.RC.1 as represented in  CVE-2024-38229 https://www.cve.org/CVERecord . Additionally, if you've deployed self-contained applications https://docs.microsoft.com/dotnet/core/deploying/#self-contained-deployments-scd  targeting any of the impacted versions, these applications are also vulnerable and must be recompiled and redeployed. NOTE: This CVE only represents End Of Life (EOL) software components. The vendor, Microsoft, has indicated there will be no future updates nor support provided upon inquiry.
CVE-2013-10047 3 Microsoft, Miniweb2, Miniweb Http Server Project 3 Windows, Miniweb, Miniweb Http Server 2026-04-15 N/A
An unrestricted file upload vulnerability exists in MiniWeb HTTP Server <= Build 300 that allows unauthenticated remote attackers to upload arbitrary files to the server’s filesystem. By abusing the upload handler and crafting a traversal path, an attacker can place a malicious .exe in system32, followed by a .mof file in the WMI directory. This triggers execution of the payload with SYSTEM privileges via the Windows Management Instrumentation service. The exploit is only viable on Windows versions prior to Vista.
CVE-2025-4952 2 Eset, Microsoft 13 Endpoint Antivirus, Endpoint Security, File Security and 10 more 2026-04-15 N/A
Tampering of the registry entries might have led to preventing the ESET security products from starting correctly on the next system startup or to unauthorized changes in the product's configuration.
CVE-2025-61871 2 Buffalo, Microsoft 2 Navigator2, Windows 2026-04-15 N/A
NAS Navigator2 Windows version by BUFFALO INC. registers a Windows service with an unquoted file path. A user with the write permission on the root directory of the system drive may execute arbitrary code with SYSTEM privilege.
CVE-2025-36853 1 Microsoft 1 .net 2026-04-15 7.5 High
A vulnerability (CVE-2025-21172) exists in msdia140.dll due to integer overflow and heap-based overflow. Per CWE-122: Heap-based Buffer Overflow, a heap overflow condition is a buffer overflow, where the buffer that can be overwritten is allocated in the heap portion of memory, generally meaning that the buffer was allocated using a routine such as malloc().‍ Per CWE-190: Integer Overflow or Wraparound, is when a product performs a calculation that can produce an integer overflow or wraparound when the logic assumes that the resulting value will always be larger than the original value. This occurs when an integer value is incremented to a value that is too large to store in the associated representation. When this occurs, the value may become a very small or negative number. NOTE: This CVE affects only End Of Life (EOL) software components. The vendor, Microsoft, has indicated there will be no future updates nor support provided upon inquiry.
CVE-2025-36855 1 Microsoft 1 .net 2026-04-15 8.8 High
A vulnerability ( CVE-2025-21176 https://www.cve.org/CVERecord ) exists in DiaSymReader.dll due to buffer over-read. Per CWE-126: Buffer Over-read https://cwe.mitre.org/data/definitions/126.html , Buffer Over-read is when a product reads from a buffer using buffer access mechanisms such as indexes or pointers that reference memory locations after the targeted buffer. This issue affects EOL ASP.NET 6.0.0 <= 6.0.36 as represented in this CVE, as well as 8.0.0 <= 8.0.11 & <= 9.0.0 as represented in CVE-2025-21176. Additionally, if you've deployed self-contained applications https://docs.microsoft.com/dotnet/core/deploying/#self-contained-deployments-scd  targeting any of the impacted versions, these applications are also vulnerable and must be recompiled and redeployed. NOTE: This CVE affects only End Of Life (EOL) software components. The vendor, Microsoft, has indicated there will be no future updates nor support provided upon inquiry.
CVE-2024-30164 3 Apple, Codesys, Microsoft 3 Macos, Linux, Windows 2026-04-15 6.7 Medium
Amazon AWS Client VPN has a buffer overflow that could potentially allow a local actor to execute arbitrary commands with elevated permissions. This is resolved in 3.11.1 on Windows, 3.9.1 on macOS, and 3.12.1 on Linux. NOTE: although the macOS resolution is the same as for CVE-2024-30165, this vulnerability on macOS is not the same as CVE-2024-30165.
CVE-2025-36463 3 Broadcom, Dell, Microsoft 3 Bcm5820x, Controlvault3, Windows 2026-04-15 7.3 High
Multiple out-of-bounds read and write vulnerabilities exist in the ControlVault WBDI Driver Broadcom Storage Adapter functionality of Dell ControlVault3 prior to 5.15.14.19 and Dell ControlVault3 Plus prior to 6.2.36.47. A specially crafted WinBioControlUnit call can lead to memory corruption. An attacker can issue an api call to trigger this vulnerability. This vulnerability is triggered when submitting a `WinBioControlUnit` call to the StorageAdapter with the ControlCode 4 (`WBIO_USH_ADD_RECORD`) and with an invalid `SendBufferSize`.
CVE-2025-9611 1 Microsoft 1 Playwright 2026-04-15 N/A
Microsoft Playwright MCP Server versions prior to 0.0.40 fails to validate the Origin header on incoming connections. This allows an attacker to perform a DNS rebinding attack via a victim’s web browser and send unauthorized requests to a locally running MCP server, resulting in unintended invocation of MCP tool endpoints.
CVE-2025-42888 2 Microsoft, Sap 4 Windows, Gui, Gui For Windows and 1 more 2026-04-15 5.5 Medium
SAP GUI for Windows may allow a highly privileged user on the affected client PC to locally access sensitive information stored in process memory during runtime.This vulnerability has a high impact on confidentiality, with no impact on integrity and availability.