Total
6747 CVE
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2026-50043 | 1 Seiko-sol | 2 Skybridge Mb-a100, Skybridge Mb-a110 | 2026-08-02 | N/A |
| Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in SkyBridge MB-A100/MB-A110. If this vulnerability is exploited, an arbitrary OS command may be executed by an attacker who can log in to the product with an administrative privilege. | ||||
| CVE-2026-49814 | 1 Dell | 2 Data Domain Operating System, Powerprotect Data Domain | 2026-08-01 | 7.2 High |
| Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to arbitrary command execution. | ||||
| CVE-2026-49813 | 1 Dell | 2 Data Domain Operating System, Powerprotect Data Domain | 2026-08-01 | 6.7 Medium |
| Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special elements used in an OS command ('OS command Injection') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary command execution. | ||||
| CVE-2026-12195 | 1 Myvestacp | 1 Myvesta | 2026-08-01 | N/A |
| myVesta is affected by an authenticated remote code execution vulnerability. Low privileged users can insert arbitrary commands as a part of the v_ftp_user parameter when deleting FTP usernames. This could result in the execution of commands as the admin user or takevoer of the admin user in myVesta. | ||||
| CVE-2026-56688 | 1 Dell | 1 Powerflex Manager | 2026-08-01 | 9.1 Critical |
| Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability during OS Repository processing to achieve arbitrary command execution as root, potentially leading to full appliance compromise and lateral movement into managed infrastructure. | ||||
| CVE-2026-42168 | 1 Abhishek-ram | 1 Django-pyas2 | 2026-08-01 | 9.1 Critical |
| django-pyas2 through 1.2.3 is vulnerable to OS command injection via the cmd_receive and cmd_send fields on the Partner model. These fields are passed directly to os.system() in pyas2/utils.py without sanitization, allowing an authenticated admin user to execute arbitrary commands on the server when an AS2 message is received or sent. | ||||
| CVE-2026-44106 | 2 Phoenix Contact, Phoenixcontact | 8 Charx Sec 3000, Charx Sec 3050, Charx Sec 3100 and 5 more | 2026-07-31 | 7.8 High |
| A privilege escalation vulnerability in the init-script for user-applications allows a low-privileged local user to execute arbitrary commands as root, resulting in full system compromise. | ||||
| CVE-2026-44096 | 2 Phoenix Contact, Phoenixcontact | 8 Charx Sec 3000, Charx Sec 3050, Charx Sec 3100 and 5 more | 2026-07-31 | 7.8 High |
| A privilege escalation vulnerability in udhcpc allows a local user "charx-web" to execute arbitrary commands as root, resulting in full system compromise. | ||||
| CVE-2026-0631 | 1 Tp-link | 2 Archer Be230, Archer Be230 Firmware | 2026-07-31 | 8.0 High |
| An OS Command Injection vulnerability in TP-Link Archer BE230 v1.2(vpn modules) and OpenVPN of AXE75 v1 allows an adjacent authenticated attacker to execute arbitrary code. Successful exploitation could allow an attacker to gain full administrative control of the device, resulting in severe compromise of configuration integrity, network security, and service availability. This CVE covers one of multiple distinct OS command injection issues identified across separate code paths. Although similar in nature, each instance is tracked under a unique CVE ID. This issue affects Archer BE230 v1.2 < 1.2.4 Build 20251218 rel.70420 and Archer AXE75 v1 < 1.5.6 Build 20260623. | ||||
| CVE-2026-12161 | 1 Devolutions | 1 Remote Desktop Manager | 2026-07-31 | 8.8 High |
| Improper input validation in the SSH Elevate Shell feature allows an authenticated user with permission to create or modify a shared SSH entry to execute arbitrary commands on a remote SSH host using stored elevation credentials via a crafted alternate username and user interaction with the Elevate Shell action. This affects : - Remote Desktop Manager 2026.2.5.0 through 2026.2.7.0 - Remote Desktop Manager 2026.1.23.0 and earlier | ||||
| CVE-2026-54483 | 1 Dell | 2 Data Domain Operating System, Powerprotect Data Domain | 2026-07-31 | 6.7 Medium |
| Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.6, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special elements used in an OS command ('OS command Injection') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution. | ||||
| CVE-2026-26355 | 1 Dell | 2 Data Domain Operating System, Powerprotect Data Domain | 2026-07-31 | 6.5 Medium |
| Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special Elements used in an OS command ('OS command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to command execution. | ||||
| CVE-2026-53478 | 1 Dell | 2 Data Domain Operating System, Powerprotect Data Domain | 2026-07-31 | 7.2 High |
| Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special elements used in an OS command ('OS command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to command execution. | ||||
| CVE-2026-53479 | 1 Dell | 2 Data Domain Operating System, Powerprotect Data Domain | 2026-07-31 | 7.2 High |
| Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special elements used in an OS command ('OS command Injection') vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to protection mechanism bypass. This is a Critical vulnerability as it allows an attacker to invoke arbitrary command execution with root privileges; so Dell recommends customers to upgrade at the earliest opportunity. | ||||
| CVE-2026-24697 | 1 Cisco | 6 Rv110w, Rv110w Firmware, Rv130 and 3 more | 2026-07-31 | 7.2 High |
| An OS command injection vulnerability exists in the start_bonjour() function of the "rc" binary in Cisco RV130/RV130W with firmware 1.0.3.55 and RV110W routers with firmware 1.2.2.5 / 1.2.2.8. The wan_hostname configuration parameter is not properly sanitized, which could allow an authenticated remote attacker to execute arbitrary OS commands with root privileges. | ||||
| CVE-2026-24698 | 1 Cisco | 6 Rv110w, Rv110w Firmware, Rv130 and 3 more | 2026-07-31 | 7.2 High |
| An OS command injection vulnerability exists in the save_syslog_to_file() function of the "httpd" binary in Cisco RV130/RV130W with firmware 1.0.3.55 and RV110W routers with firmware 1.2.2.5 / 1.2.2.8. The model_name configuration parameter is not properly sanitized, which could allow an authenticated remote attacker to execute arbitrary OS commands with root privileges. | ||||
| CVE-2026-24700 | 1 Cisco | 6 Rv110w, Rv110w Firmware, Rv130 and 3 more | 2026-07-31 | 7.2 High |
| An OS command injection vulnerability exists in the start_lltd() function of the "rc" binary in Cisco RV130/RV130W with firmware 1.0.3.55 and RV110W routers with firmware 1.2.2.5 / 1.2.2.8. The machine_name configuration parameter is not properly sanitized, which could allow an authenticated remote attacker to execute arbitrary OS commands with root privileges. | ||||
| CVE-2026-22622 | 1 Eaton | 1 Padm | 2026-07-31 | 8.8 High |
| Improper input validation in one of the session management interface of Eaton's Tripp Lite series PADM firmware could allow an authenticated user to elevate privileges resulting in unrestricted access to the device. | ||||
| CVE-2026-12940 | 2 Ibm, Langflow | 2 Langflow Oss, Langflow | 2026-07-31 | 9.8 Critical |
| IBM Langflow OSS 1.0.0 through 1.10.1 are vulnerable to unauthenticated remote code execution via environment variable injection in the MCP (Model Context Protocol) stdio launcher. The vulnerability exists in src/lfx/src/lfx/base/mcp/util.py where the DANGEROUS_ENV_VARS blocklist fails to include SHELLOPTS , BASHOPTS , and PS4 environment variables. | ||||
| CVE-2026-14371 | 1 Lenovo | 1 Xclarity Integrator For Microsoft Windows Admin Center | 2026-07-31 | N/A |
| The Lenovo XClarity Integrator for Windows Admin Center plugin version 5.1.1 and below running on the WAC Gateway is vulnerable to Powershell Command Injection when establishing remote PowerShell commands. | ||||