Filtered by vendor Tenda
Subscriptions
Filtered by product Ac10 Firmware
Subscriptions
Total
92 CVE
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-25674 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-03-17 | 9.8 Critical |
| Tenda AC10 V1.0 V15.03.06.23 is vulnerable to Buffer Overflow in form_fast_setting_wifi_set via the parameter ssid. | ||||
| CVE-2024-32317 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-03-17 | 7.5 High |
| Tenda AC10 v4.0 V16.03.10.13 and V16.03.10.20 firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function. | ||||
| CVE-2024-25373 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-03-17 | 4.6 Medium |
| Tenda AC10V4.0 V16.03.10.20 was discovered to contain a stack overflow via the page parameter in the sub_49B384 function. | ||||
| CVE-2023-27016 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-02-12 | 9.8 Critical |
| Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the R7WebsSecurityHandler function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. | ||||
| CVE-2023-27015 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-02-12 | 9.8 Critical |
| Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_4A75C0 function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. | ||||
| CVE-2023-27014 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-02-12 | 9.8 Critical |
| Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_46AC38 function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. | ||||
| CVE-2023-27013 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-02-12 | 9.8 Critical |
| Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the get_parentControl_list_Info function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. | ||||
| CVE-2023-27012 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-02-12 | 9.8 Critical |
| Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the setSchedWifi function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. | ||||
| CVE-2023-27017 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-02-12 | 9.8 Critical |
| Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_45DC58 function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. | ||||
| CVE-2023-27019 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-02-12 | 9.8 Critical |
| Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_458FBC function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. | ||||
| CVE-2023-27021 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-02-12 | 9.8 Critical |
| Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the formSetFirewallCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. | ||||
| CVE-2023-27020 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-02-12 | 9.8 Critical |
| Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the saveParentControlInfo function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. | ||||
| CVE-2023-27018 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-02-12 | 9.8 Critical |
| Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_45EC1C function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. | ||||
| CVE-2024-2581 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-01-22 | 8.8 High |
| A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257081 was assigned to this vulnerability. | ||||
| CVE-2023-34568 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-01-06 | 6.7 Medium |
| Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter time at /goform/PowerSaveSet. | ||||
| CVE-2023-34566 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-01-06 | 9.8 Critical |
| Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter time at /goform/saveParentControlInfo. | ||||
| CVE-2023-34571 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-01-06 | 6.7 Medium |
| Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter shareSpeed at /goform/WifiGuestSet. | ||||
| CVE-2023-34570 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-01-06 | 6.7 Medium |
| Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter devName at /goform/SetOnlineDevName. | ||||
| CVE-2023-34569 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-01-06 | 6.7 Medium |
| Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list at /goform/SetNetControlList. | ||||
| CVE-2023-34567 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-01-06 | 6.7 Medium |
| Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list at /goform/SetVirtualServerCfg. | ||||