Filtered by vendor Moxa
Subscriptions
Total
306 CVE
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2016-8719 | 1 Moxa | 2 Awk-3131a, Awk-3131a Firmware | 2025-04-20 | 6.1 Medium |
| An exploitable reflected Cross-Site Scripting vulnerability exists in the Web Application functionality of Moxa AWK-3131A Wireless Access Point running firmware 1.1. Specially crafted input, in multiple parameters, can cause a malicious scripts to be executed by a victim. | ||||
| CVE-2016-9332 | 1 Moxa | 1 Softcms | 2025-04-20 | N/A |
| An issue was discovered in Moxa SoftCMS versions prior to Version 1.6. Moxa SoftCMS Webserver does not properly validate input. An attacker could provide unexpected values and cause the program to crash or excessive consumption of resources could result in a denial-of-service condition. | ||||
| CVE-2016-8359 | 1 Moxa | 19 Iologik E1200 Series Firmware, Iologik E1210, Iologik E1211 and 16 more | 2025-04-20 | 6.1 Medium |
| An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. The web application fails to sanitize user input, which may allow an attacker to inject script or execute arbitrary code (CROSS-SITE SCRIPTING). | ||||
| CVE-2016-8363 | 1 Moxa | 28 Awk-1121, Awk-1121 Firmware, Awk-1127 and 25 more | 2025-04-20 | N/A |
| An issue was discovered in Moxa OnCell OnCellG3470A-LTE, AWK-1131A/3131A/4131A Series, AWK-3191 Series, AWK-5232/6232 Series, AWK-1121/1127 Series, WAC-1001 V2 Series, WAC-2004 Series, AWK-3121-M12-RTG Series, AWK-3131-M12-RCC Series, AWK-5232-M12-RCC Series, TAP-6226 Series, AWK-3121/4121 Series, AWK-3131/4131 Series, and AWK-5222/6222 Series. User is able to execute arbitrary OS commands on the server. | ||||
| CVE-2016-8372 | 1 Moxa | 19 Iologik E1200 Series Firmware, Iologik E1210, Iologik E1211 and 16 more | 2025-04-20 | 8.1 High |
| An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. A password is transmitted in a format that is not sufficiently secure. | ||||
| CVE-2016-9346 | 1 Moxa | 6 Miineport E1, Miineport E1 Firmware, Miineport E2 and 3 more | 2025-04-20 | N/A |
| An issue was discovered in Moxa MiiNePort E1 versions prior to 1.8, E2 versions prior to 1.4, and E3 versions prior to 1.1. Configuration data are stored in a file that is not encrypted. | ||||
| CVE-2017-13698 | 1 Moxa | 2 Eds-g512e, Eds-g512e Firmware | 2025-04-20 | N/A |
| An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. An attacker could extract public and private keys from the firmware image available on the MOXA website and could use them against a production switch that has the default keys embedded. | ||||
| CVE-2017-13701 | 1 Moxa | 2 Eds-g512e, Eds-g512e Firmware | 2025-04-20 | N/A |
| An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. The backup file contains sensitive information in a insecure way. There is no salt for password hashing. Indeed passwords are stored without being ciphered with a timestamped ciphering method. | ||||
| CVE-2016-8718 | 1 Moxa | 2 Awk-3131a, Awk-3131a Firmware | 2025-04-20 | 8.8 High |
| An exploitable Cross-Site Request Forgery vulnerability exists in the Web Application functionality of Moxa AWK-3131A Wireless Access Point running firmware 1.1. A specially crafted form can trick a client into making an unintentional request to the web server which will be treated as an authentic request. | ||||
| CVE-2016-8720 | 1 Moxa | 2 Awk-3131a, Awk-3131a Firmware | 2025-04-20 | 4.3 Medium |
| An exploitable HTTP Header Injection vulnerability exists in the Web Application functionality of the Moxa AWK-3131A Wireless Access Point running firmware 1.1. A specially crafted HTTP request can inject a payload in the bkpath parameter which will be copied in to Location header of the HTTP response. | ||||
| CVE-2017-16727 | 1 Moxa | 4 Nport W2150a, Nport W2150a Firmware, Nport W2250a and 1 more | 2025-04-20 | N/A |
| A Credentials Management issue was discovered in Moxa NPort W2150A versions prior to 1.11, and NPort W2250A versions prior to 1.11. The default password is empty on the device. An unauthorized user can access the device without a password. An unauthorized user has the ability to completely compromise the confidentiality and integrity of the wireless traffic. | ||||
| CVE-2016-8724 | 1 Moxa | 2 Awk-3131a, Awk-3131a Firmware | 2025-04-20 | 5.3 Medium |
| An exploitable information disclosure vulnerability exists in the serviceAgent functionality of Moxa AWK-3131A Wireless Access Point running firmware 1.1. A specially crafted TCP query will allow an attacker to retrieve potentially sensitive information. | ||||
| CVE-2016-8712 | 1 Moxa | 2 Awk-3131a, Awk-3131a Firmware | 2025-04-20 | 8.1 High |
| An exploitable nonce reuse vulnerability exists in the Web Application functionality of Moxa AWK-3131A Wireless AP running firmware 1.1. The device uses one nonce for all session authentication requests and only changes the nonce if the web application has been idle for 300 seconds. | ||||
| CVE-2016-9333 | 1 Moxa | 1 Softcms | 2025-04-20 | N/A |
| An issue was discovered in Moxa SoftCMS versions prior to Version 1.6. The SoftCMS Application does not properly sanitize input that may allow a remote attacker access to SoftCMS with administrator's privilege through specially crafted input (SQL INJECTION). | ||||
| CVE-2016-9348 | 1 Moxa | 51 Nport 5100 Series Firmware, Nport 5100a Series Firmware, Nport 5110 and 48 more | 2025-04-20 | N/A |
| An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5400 Series versions prior to 3.11, NPort 5600 Series versions prior to 3.7, NPort 5100A Series & NPort P5150A versions prior to 1.3, NPort 5200A Series versions prior to 1.3, NPort 5150AI-M12 Series versions prior to 1.2, NPort 5250AI-M12 Series versions prior to 1.2, NPort 5450AI-M12 Series versions prior to 1.2, NPort 5600-8-DT Series versions prior to 2.4, NPort 5600-8-DTL Series versions prior to 2.4, NPort 6x50 Series versions prior to 1.13.11, NPort IA5450A versions prior to v1.4. A configuration file contains parameters that represent passwords in plaintext. | ||||
| CVE-2017-13703 | 1 Moxa | 2 Eds-g512e, Eds-g512e Firmware | 2025-04-20 | N/A |
| An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. A denial of service may occur. | ||||
| CVE-2017-7455 | 1 Moxa | 1 Mxview | 2025-04-20 | N/A |
| Moxa MXView 2.8 allows remote attackers to read web server's private key file, no access control. | ||||
| CVE-2016-8716 | 1 Moxa | 2 Awk-3131a, Awk-3131a Firmware | 2025-04-20 | 7.5 High |
| An exploitable Cleartext Transmission of Password vulnerability exists in the Web Application functionality of Moxa AWK-3131A Wireless Access Point running firmware 1.1. The Change Password functionality of the Web Application transmits the password in cleartext. An attacker capable of intercepting this traffic is able to obtain valid credentials. | ||||
| CVE-2016-9344 | 1 Moxa | 6 Miineport E1, Miineport E1 Firmware, Miineport E2 and 3 more | 2025-04-20 | N/A |
| An issue was discovered in Moxa MiiNePort E1 versions prior to 1.8, E2 versions prior to 1.4, and E3 versions prior to 1.1. An attacker may be able to brute force an active session cookie to be able to download configuration files. | ||||
| CVE-2017-13702 | 1 Moxa | 2 Eds-g512e, Eds-g512e Firmware | 2025-04-20 | N/A |
| An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. Cookies can be stolen, manipulated, and reused. | ||||