Filtered by vendor Rockwellautomation
Subscriptions
Total
390 CVE
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-11697 | 1 Rockwellautomation | 1 Studio 5000 Simulation Interface | 2026-04-15 | N/A |
| A local code execution security issue exists within Studio 5000® Simulation Interface™ via the API. This vulnerability allows any Windows user on the system to extract files using path traversal sequences, resulting in execution of scripts with Administrator privileges on system reboot. | ||||
| CVE-2025-13824 | 1 Rockwellautomation | 3 Micro820, Micro850, Micro870 | 2026-04-15 | N/A |
| A security issue exists due to improper handling of malformed CIP packets during fuzzing. The controller enters a hard fault with solid red Fault LED and becomes unresponsive. Upon power cycle, the controller will enter recoverable fault where the MS LED and Fault LED become flashing red and reports fault code 0xF019. To recover, clear the fault. | ||||
| CVE-2025-9368 | 1 Rockwellautomation | 1 432es-ig3 Series A | 2026-04-15 | N/A |
| A security issue exists within 432ES-IG3 Series A, which affects GuardLink® EtherNet/IP Interface, resulting in denial-of-service. A manual power cycle is required to recover the device. | ||||
| CVE-2025-9041 | 1 Rockwellautomation | 1 Flex 5000 Io | 2026-04-15 | N/A |
| A security issue exists due to improper handling of CIP Class 32’s request when a module is inhibited on the 5094-IF8 device. It causes the module to enter a fault state with the Module LED flashing red. Upon un-inhibiting, the module returns a connection fault (Code 16#0010), and the module cannot recover without a power cycle. | ||||
| CVE-2025-7973 | 1 Rockwellautomation | 1 Factorytalk View | 2026-04-15 | N/A |
| A security issue exists in FactoryTalk ViewPoint version 14.0 or below due to improper handling of MSI repair operations. During a repair, attackers can hijack the cscript.exe console window, which runs with SYSTEM privileges. This can be exploited to spawn an elevated command prompt, enabling full privilege escalation. | ||||
| CVE-2025-11085 | 1 Rockwellautomation | 1 Factorytalk | 2026-04-15 | N/A |
| A security issue exists within DataMosaix™ Private Cloud allowing for Persistent XSS. This vulnerability can result in the execution of malicious JavaScript, allowing for account takeover, credential theft, or redirection to a malicious website. | ||||
| CVE-2025-14376 | 1 Rockwellautomation | 1 Verve Asset Manager | 2026-04-15 | N/A |
| A security issue was discovered within the legacy ADI server component of Verve Asset Manager, caused by plaintext secrets stored in environment variables on the ADI server. This component has been retired and has been optional since the 1.36 release in 2024. | ||||
| CVE-2025-7971 | 1 Rockwellautomation | 1 Studio 5000 Logix Designer | 2026-04-15 | N/A |
| A security issues exists within Studio 5000 Logix Designer due to unsafe handling of environment variables. If the specified path lacks a valid file, Logix Designer crashes; However, it may be possible to execute malicious code without triggering a crash. | ||||
| CVE-2025-7353 | 1 Rockwellautomation | 1 Controllogix | 2026-04-15 | N/A |
| A security issue exists due to the web-based debugger agent enabled on Rockwell Automation ControlLogix® Ethernet Modules. If a specific IP address is used to connect to the WDB agent, it can allow remote attackers to perform memory dumps, modify memory, and control execution flow. | ||||
| CVE-2024-10944 | 1 Rockwellautomation | 1 Factorytalk Updater | 2026-04-15 | 8.4 High |
| A Remote Code Execution vulnerability exists in the affected product. The vulnerability requires a high level of permissions and exists due to improper input validation resulting in the possibility of a malicious Updated Agent being deployed. | ||||
| CVE-2025-7350 | 1 Rockwellautomation | 1 Stratix | 2026-04-15 | N/A |
| A security issue affecting multiple Cisco devices also directly impacts Stratix® 5410, 5700, and 8000 devices. This can lead to remote code execution by uploading and running malicious configurations without authentication. | ||||
| CVE-2019-25276 | 1 Rockwellautomation | 2 Factorytalk Activation, Studio | 2026-04-15 | 7.8 High |
| Studio 5000 Logix Designer 30.01.00 contains an unquoted service path vulnerability in the FactoryTalk Activation Service that allows local users to potentially execute code with elevated privileges. Attackers can exploit the unquoted path in C:\Program Files (x86)\Rockwell Software\FactoryTalk Activation\ to inject malicious code that would execute with LocalSystem permissions. | ||||
| CVE-2025-7693 | 1 Rockwellautomation | 1 Micro800 | 2026-04-15 | N/A |
| A security issue exists due to improper handling of malformed CIP Forward Close packets during fuzzing. The controller enters a solid red Fault LED state and becomes unresponsive. Upon power cycle, the controller will enter recoverable fault where the MS LED and Fault LED become flashing red and reports fault code 0xF015. To recover, clear the fault. | ||||
| CVE-2025-11743 | 1 Rockwellautomation | 1 Compactlogix 5370 | 2026-04-15 | N/A |
| A denial-of-service security issue in the affected product. The security issue occurs when a malformed CIP forward open message is sent. This could result in a major nonrecoverable fault a restart is required to recover. | ||||
| CVE-2025-12807 | 1 Rockwellautomation | 1 Factorytalk Datamosaix Private Cloud | 2026-04-15 | N/A |
| A security issue was discovered in DataMosaix Private Cloud, allowing users with low privilege to perform sensitive database operations through exposed API endpoints. | ||||
| CVE-2025-9124 | 1 Rockwellautomation | 1 Compact Guardlogix 5370 | 2026-04-15 | N/A |
| A denial-of-service security issue in the affected product. The security issue stems from a fault occurring when a crafted CIP unconnected explicit message is sent. This can result in a major non-recoverable fault. | ||||
| CVE-2025-9036 | 1 Rockwellautomation | 1 Factorytalk Action Manager | 2026-04-15 | N/A |
| A security issue in the runtime event system allows unauthenticated connections to receive a reusable API token. This token is broadcasted over a WebSocket and can be intercepted by any local client listening on the connection. | ||||
| CVE-2024-9412 | 1 Rockwellautomation | 1 Verve Asset Manager | 2026-04-15 | N/A |
| An improper authorization vulnerability exists in the Rockwell Automation affected products that could allow an unauthorized user to sign in. While removal of all role mappings is unlikely, it could occur in the case of unexpected or accidental removal by the administrator. If exploited, an unauthorized user could access data they previously but should no longer have access to. | ||||
| CVE-2025-11696 | 1 Rockwellautomation | 1 Studio 5000 Simulation Interface | 2026-04-15 | N/A |
| A local server-side request forgery (SSRF) security issue exists within Studio 5000® Simulation Interface™ via the API. This vulnerability allows any Windows user on the system to trigger outbound SMB requests, enabling the capture of NTLM hashes. | ||||
| CVE-2024-6079 | 1 Rockwellautomation | 1 Emulate3d | 2026-04-15 | N/A |
| A vulnerability exists in the Rockwell Automation Emulate3D™, which could be leveraged to execute a DLL Hijacking attack. The application loads shared libraries, which are readable and writable by any user. If exploited, a malicious user could leverage a malicious dll and perform a remote code execution attack. | ||||