Total
5052 CVE
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2026-4432 | 2 Wordpress, Yithemes | 2 Wordpress, Yith Woocommerce Wishlist | 2026-04-15 | 6.5 Medium |
| The YITH WooCommerce Wishlist WordPress plugin before 4.13.0 does not properly validate wishlist ownership in the save_title() AJAX handler before allowing wishlist renaming operations. The function only checks for a valid nonce, which is publicly exposed in the page source of the /wishlist/ page, making it possible for unauthenticated attackers to rename any wishlist belonging to any user on the site. | ||||
| CVE-2025-15433 | 2 Sharedfilespro, Wordpress | 2 Shared Files, Wordpress | 2026-04-15 | 6.8 Medium |
| The Shared Files WordPress plugin before 1.7.58 allows users with a role as low as Contributor to download any file on the web server (such as wp-config.php) via a path traversal vector | ||||
| CVE-2024-34022 | 1 Intel | 1 Thunderbolt Share Software | 2026-04-15 | 6.7 Medium |
| Improper Access Control in some Thunderbolt(TM) Share software before version 1.0.49.9 may allow an authenticated user to potentially enable escalation of privilege via local access. | ||||
| CVE-2023-29113 | 2026-04-15 | 6.3 Medium | ||
| The MIB3 infotainment unit used in Skoda and Volkswagen vehicles does not incorporate any privilege separation for the proprietary inter-process communication mechanism, leaving attackers with presence in the system an ability to undermine access control restrictions implemented at the operating system level. The vulnerability was originally discovered in Skoda Superb III car with MIB3 infotainment unit OEM part number 3V0035820. The list of affected MIB3 OEM part numbers is provided in the referenced resources. | ||||
| CVE-2024-27200 | 2026-04-15 | 4.4 Medium | ||
| Improper access control in some Intel(R) Granulate(TM) software before version 4.30.1 may allow a authenticated user to potentially enable escalation of privilege via local access. | ||||
| CVE-2024-47976 | 1 Solidigm | 12 D5 P4320 Firmware, D5 P4326 Firmware, D5 P5316 Firmware and 9 more | 2026-04-15 | 6.7 Medium |
| Improper access removal handling in firmware of some Solidigm DC Products may allow an attacker with physical access to gain unauthorized access. | ||||
| CVE-2025-24313 | 2 Intel, Kubernetes | 2 Device Plugins For Kubernetes, Kubernetes | 2026-04-15 | 4.4 Medium |
| Improper access control for some Device Plugins for Kubernetes software maintained by Intel before version 0.32.0 may allow a privileged user to potentially enable denial of service via local access. | ||||
| CVE-2025-66223 | 1 Openobserve | 1 Openobserve | 2026-04-15 | N/A |
| OpenObserve is a cloud-native observability platform. Prior to version 0.16.0, organization invitation tokens do not expire once issued, remain valid even after the invited user is removed from the organization, and allow multiple invitations to the same email with different roles where all issued links remain valid simultaneously. This results in broken access control where a removed or demoted user can regain access or escalate privileges. This issue has been patched in version 0.16.0. | ||||
| CVE-2025-56406 | 2 Neo4j, Neo4j-contrib | 2 Neo4j, Mcp-neo4j | 2026-04-15 | 7.5 High |
| An issue was discovered in mcp-neo4j 0.3.0 allowing attackers to obtain sensitive information or execute arbitrary commands via the SSE service. NOTE: the Supplier's position is that authentication is not mandatory for MCP servers, and the mcp-neo4j MCP server is only intended for use in a local environment where authentication realistically would not be needed. Also, the Supplier provides middleware to help isolate the MCP server from external access (if needed). | ||||
| CVE-2025-69907 | 1 Newgensoft | 1 Omnidocs | 2026-04-15 | 7.5 High |
| An unauthenticated information disclosure vulnerability exists in Newgen OmniDocs due to missing authentication and access control on the /omnidocs/GetListofCabinet API endpoint. A remote attacker can access this endpoint without valid credentials to retrieve sensitive internal configuration information, including cabinet names and database-related metadata. This allows unauthorized enumeration of backend deployment details and may facilitate further targeted attacks. | ||||
| CVE-2024-40117 | 1 Solar-log | 1 Solar-log 1000 Firmware | 2026-04-15 | 9.8 Critical |
| Incorrect access control in Solar-Log 1000 before v2.8.2 and build 52- 23.04.2013 allows attackers to obtain Administrative privileges via connecting to the web administration server. Not existing for SL 200, 500, 1000 / fixed in 4.2.8 for SL 250, 300, 1200, 2000, SL 50 Gateway / fixed in 5.1.2 / 6.0.0 for SL Base. | ||||
| CVE-2024-36438 | 1 Elinksmart | 1 Smart Cabinet Lock | 2026-04-15 | 7.3 High |
| eLinkSmart Hidden Smart Cabinet Lock 2024-05-22 has Incorrect Access Control and fails to perform an authorization check which can lead to card duplication and other attacks. | ||||
| CVE-2025-10371 | 2 Echarge, Hardy-barth | 2 Salia Plcc, Cph2 Echarge | 2026-04-15 | 7.3 High |
| A security flaw has been discovered in eCharge Hardy Barth Salia PLCC up to 2.3.81. This issue affects some unknown processing of the file /api.php. The manipulation of the argument setrfidlist results in unrestricted upload. The attack may be performed from remote. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-12984 | 2026-04-15 | 5.3 Medium | ||
| A vulnerability classified as problematic has been found in Amcrest IP2M-841B, IP2M-841W, IPC-IP2M-841B, IPC-IP3M-943B, IPC-IP3M-943S, IPC-IP3M-HX2B and IPC-IPM-721S up to 20241211. This affects an unknown part of the file /web_caps/webCapsConfig of the component Web Interface. The manipulation leads to information disclosure. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-46412 | 1 Getrebuild | 1 Rebuild | 2026-04-15 | 6.5 Medium |
| Incorrect access control in the prehandle function of Rebuild v3.7.7 allows attackers to bypass authentication via a crafted GET request sent to /commons/ip-location. | ||||
| CVE-2025-57266 | 1 Thrivex | 1 Blog | 2026-04-15 | 9.8 Critical |
| An issue was discovered in file AssistantController.java in ThriveX Blogging Framework 2.5.9 thru 3.1.3 allowing unauthenticated attackers to gain sensitive information such as API Keys via the /api/assistant/list endpoint. | ||||
| CVE-2022-45929 | 1 Northern.tech | 1 Mender | 2026-04-15 | 8.8 High |
| Northern.tech Mender 3.3.x before 3.3.2, 3.5.x before 3.5.0, and 3.6.x before 3.6.0 has Incorrect Access Control and allows users to change their roles and could allow privilege escalation from a low-privileged read-only user to a high-privileged user. | ||||
| CVE-2023-51786 | 1 Lustre | 1 Lustre | 2026-04-15 | 9.1 Critical |
| An issue was discovered in Lustre versions 2.13.x, 2.14.x, and 2.15.x before 2.15.4, allows attackers to escalate privileges and obtain sensitive information via Incorrect Access Control. | ||||
| CVE-2024-21483 | 2026-04-15 | 4.6 Medium | ||
| A vulnerability has been identified in SENTRON 7KM PAC3120 AC/DC (7KM3120-0BA01-1DA0) (All versions >= V3.2.3 < V3.2.4 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)), SENTRON 7KM PAC3120 DC (7KM3120-1BA01-1EA0) (All versions >= V3.2.3 < V3.2.4 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)), SENTRON 7KM PAC3220 AC/DC (7KM3220-0BA01-1DA0) (All versions >= V3.2.3 < V3.2.4 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)), SENTRON 7KM PAC3220 DC (7KM3220-1BA01-1EA0) (All versions >= V3.2.3 < V3.2.4 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)). The read out protection of the internal flash of affected devices was not properly set at the end of the manufacturing process. An attacker with physical access to the device could read out the data. | ||||
| CVE-2022-32507 | 1 Nuki | 1 Smart Lock | 2026-04-15 | 8.8 High |
| An issue was discovered on certain Nuki Home Solutions devices. Some BLE commands, which should have been designed to be only called from privileged accounts, could also be called from unprivileged accounts. This demonstrates that no access controls were implemented for the different BLE commands across the different accounts. This affects Nuki Smart Lock 3.0 before 3.3.5 and Nuki Smart Lock 2.0 before 2.12.4. | ||||