Total
2222 CVE
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2024-23618 | 1 Commscope | 2 Arris Surfboard Sbg6950ac2, Arris Surfboard Sbg6950ac2 Firmware | 2025-06-17 | 9.6 Critical |
| An arbitrary code execution vulnerability exists in Arris SURFboard SGB6950AC2 devices. An unauthenticated attacker can exploit this vulnerability to achieve code execution as root. | ||||
| CVE-2024-21619 | 1 Juniper | 105 Ex2200, Ex2200-c, Ex2200-vc and 102 more | 2025-06-17 | 5.3 Medium |
| A Missing Authentication for Critical Function vulnerability combined with a Generation of Error Message Containing Sensitive Information vulnerability in J-Web of Juniper Networks Junos OS on SRX Series and EX Series allows an unauthenticated, network-based attacker to access sensitive system information. When a user logs in, a temporary file which contains the configuration of the device (as visible to that user) is created in the /cache folder. An unauthenticated attacker can then attempt to access such a file by sending a specific request to the device trying to guess the name of such a file. Successful exploitation will reveal configuration information. This issue affects Juniper Networks Junos OS on SRX Series and EX Series: * All versions earlier than 20.4R3-S9; * 21.2 versions earlier than 21.2R3-S7; * 21.3 versions earlier than 21.3R3-S5; * 21.4 versions earlier than 21.4R3-S6; * 22.1 versions earlier than 22.1R3-S5; * 22.2 versions earlier than 22.2R3-S3; * 22.3 versions earlier than 22.3R3-S2; * 22.4 versions earlier than 22.4R3; * 23.2 versions earlier than 23.2R1-S2, 23.2R2. | ||||
| CVE-2023-5716 | 1 Asus | 1 Armoury Crate | 2025-06-17 | 9.8 Critical |
| ASUS Armoury Crate has a vulnerability in arbitrary file write and allows remote attackers to access or modify arbitrary files by sending specific HTTP requests without permission. | ||||
| CVE-2023-5253 | 1 Nozominetworks | 2 Cmc, Guardian | 2025-06-17 | 5.3 Medium |
| A missing authentication check in the WebSocket channel used for the Check Point IoT integration in Nozomi Networks Guardian and CMC, may allow an unauthenticated attacker to obtain assets data without authentication. Malicious unauthenticated users with knowledge on the underlying system may be able to extract limited asset information. | ||||
| CVE-2023-39457 | 1 Trianglemicroworks | 1 Scada Data Gateway | 2025-06-17 | N/A |
| Triangle MicroWorks SCADA Data Gateway Missing Authentication Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability. The specific flaw exists due to the lack of user authentication. The issue results from missing authentication in the default system configuration. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-20501. | ||||
| CVE-2023-39466 | 1 Trianglemicroworks | 1 Scada Data Gateway | 2025-06-17 | N/A |
| Triangle MicroWorks SCADA Data Gateway get_config Missing Authentication Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability. The specific flaw exists within the get_config endpoint. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to disclose sensitive information. Was ZDI-CAN-20797. | ||||
| CVE-2024-3701 | 1 Tecno | 1 Hios | 2025-06-17 | 9.8 Critical |
| The system application (com.transsion.kolun.aiservice) component does not perform an authentication check, which allows attackers to perform malicious exploitations and affect system services. | ||||
| CVE-2024-46506 | 1 Netalertx | 1 Netalertx | 2025-06-17 | 10 Critical |
| NetAlertX 23.01.14 through 24.x before 24.10.12 allows unauthenticated command injection via settings update because function=savesettings lacks an authentication requirement, as exploited in the wild in May 2025. This is related to settings.php and util.php. | ||||
| CVE-2024-1076 | 1 Sslzen | 1 Ssl Zen | 2025-06-17 | 6.5 Medium |
| The SSL Zen WordPress plugin before 4.6.0 does not properly prevent directory listing of the private keys folder, as it only relies on the use of .htaccess to prevent visitors from accessing the site's generated private keys, which allows an attacker to read them if the site runs on a server who doesn't support .htaccess files, like NGINX. | ||||
| CVE-2024-22449 | 1 Dell | 1 Powerscale Onefs | 2025-06-17 | 6.6 Medium |
| Dell PowerScale OneFS versions 9.0.0.x through 9.6.0.x contains a missing authentication for critical function vulnerability. A low privileged local malicious user could potentially exploit this vulnerability to gain elevated access. | ||||
| CVE-2023-51062 | 1 Qstar | 1 Archive Storage Manager | 2025-06-16 | 5.3 Medium |
| An unauthenticated log file read in the component log-smblog-save of QStar Archive Solutions RELEASE_3-0 Build 7 Patch 0 allows attackers to disclose the SMB Log contents via executing a crafted command. | ||||
| CVE-2025-5906 | 1 Code-projects | 1 Laundry System | 2025-06-13 | 7.3 High |
| A vulnerability classified as critical has been found in code-projects Laundry System 1.0. This affects an unknown part of the file /data/. The manipulation leads to missing authentication. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. | ||||
| CVE-2024-8012 | 1 Ivanti | 1 Workspace Control | 2025-06-12 | 7.8 High |
| An authentication bypass weakness in the message broker service of Ivanti Workspace Control before version 2025.2 (10.19.0.0) allows a local authenticated attacker to escalate their privileges. | ||||
| CVE-2023-47674 | 1 C-first | 56 Cfr-1004ea, Cfr-1004ea Firmware, Cfr-1008ea and 53 more | 2025-06-11 | 9.8 Critical |
| Missing authentication for critical function vulnerability in First Corporation's DVRs allows a remote unauthenticated attacker to rewrite or obtain the configuration information of the affected device. Note that updates are provided only for Late model of CFR-4EABC, CFR-4EAB, CFR-8EAB, CFR-16EAB, MD-404AB, and MD-808AB. As for the other products, apply the workaround. | ||||
| CVE-2023-42770 | 1 Redlioncontrols | 12 St-ipm-6350, St-ipm-6350 Firmware, St-ipm-8460 and 9 more | 2025-06-11 | 10 Critical |
| Red Lion SixTRAK and VersaTRAK Series RTUs with authenticated users enabled (UDR-A) any Sixnet UDR message will meet an authentication challenge over UDP/IP. When the same message is received over TCP/IP the RTU will simply accept the message with no authentication challenge. | ||||
| CVE-2023-49617 | 1 Machinesense | 2 Feverwarn, Feverwarn Firmware | 2025-06-06 | 10 Critical |
| The MachineSense application programmable interface (API) is improperly protected and can be accessed without authentication. A remote attacker could retrieve and modify sensitive information without any authentication. | ||||
| CVE-2023-49255 | 1 Hongdian | 2 H8951-4g-esp, H8951-4g-esp Firmware | 2025-06-03 | 9.8 Critical |
| The router console is accessible without authentication at "data" field, and while a user needs to be logged in in order to modify the configuration, the session state is shared. If any other user is currently logged in, the anonymous user can execute commands in the context of the authenticated one. If the logged in user has administrative privileges, it is possible to use webadmin service configuration commands to create a new admin user with a chosen password. | ||||
| CVE-2023-31033 | 1 Nvidia | 2 Dgx A100, Dgx A100 Firmware | 2025-06-03 | 6.8 Medium |
| NVIDIA DGX A100 BMC contains a vulnerability where a user may cause a missing authentication issue for a critical function by an adjacent network . A successful exploit of this vulnerability may lead to escalation of privileges, code execution, denial of service, information disclosure, and data tampering. | ||||
| CVE-2023-29060 | 2 Bd, Hp | 3 Facschorus, Hp Z2 Tower G5, Hp Z2 Tower G9 | 2025-06-03 | 5.4 Medium |
| The FACSChorus workstation operating system does not restrict what devices can interact with its USB ports. If exploited, a threat actor with physical access to the workstation could gain access to system information and potentially exfiltrate data. | ||||
| CVE-2023-29061 | 2 Bd, Hp | 3 Facschorus, Hp Z2 Tower G5, Hp Z2 Tower G9 | 2025-06-03 | 5.2 Medium |
| There is no BIOS password on the FACSChorus workstation. A threat actor with physical access to the workstation can potentially exploit this vulnerability to access the BIOS configuration and modify the drive boot order and BIOS pre-boot authentication. | ||||