Filtered by vendor Schneider-electric
Subscriptions
Total
821 CVE
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-13905 | 1 Schneider-electric | 2 Ecostruxure Process Expert, Ecostruxure Process Expert For Aveva System Platform | 2026-04-15 | N/A |
| CWE-276: Incorrect Default Permissions vulnerability exists that could cause privilege escalation through the reverse shell when one or more executable service binaries are modified in the installation folder by a local user with normal privilege upon service restart. | ||||
| CVE-2025-9997 | 1 Schneider-electric | 1 Blmon | 2026-04-15 | N/A |
| CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause command injection in BLMon that is executed in the operating system console when in a SSH session. | ||||
| CVE-2025-11567 | 1 Schneider-electric | 1 Powerchute Serial Shutdown | 2026-04-15 | N/A |
| CWE-276: Incorrect Default Permissions vulnerability exists that could cause elevated system access when the target installation folder is not properly secured. | ||||
| CVE-2025-54924 | 1 Schneider-electric | 2 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation With Advanced Reports | 2026-04-15 | 7.5 High |
| CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to sensitive data when an attacker sends a specially crafted document to a vulnerable endpoint. | ||||
| CVE-2024-9002 | 1 Schneider-electric | 1 Easergy Studio | 2026-04-15 | 7.8 High |
| CWE-269: Improper Privilege Management vulnerability exists that could cause unauthorized access, loss of confidentiality, integrity, and availability of the workstation when non-admin authenticated user tries to perform privilege escalation by tampering with the binaries | ||||
| CVE-2025-8448 | 1 Schneider-electric | 2 Ecostruxure Building Operation Enterprise Server, Ecostruxure Workstation | 2026-04-15 | N/A |
| CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause unauthorized access to sensitive credential data when an attacker is able to capture local SMB traffic between a valid user within the BMS network and the vulnerable products. | ||||
| CVE-2025-11565 | 1 Schneider-electric | 1 Powerchute Serial Shutdown | 2026-04-15 | N/A |
| CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause elevated system access when a Web Admin user on the local network tampers with the POST /REST/UpdateJRE request payload. | ||||
| CVE-2025-8453 | 1 Schneider-electric | 2 Saitel Dp, Saitel Dr | 2026-04-15 | 6.7 Medium |
| CWE-269: Improper Privilege Management vulnerability exists that could cause privilege escalation and arbitrary code execution when a privileged engineer user with console access modifies a configuration file used by a root-level daemon to execute custom scripts. | ||||
| CVE-2025-5296 | 1 Schneider-electric | 1 Software Update Utility | 2026-04-15 | 7.3 High |
| CWE-59: Improper Link Resolution Before File Access ('Link Following') vulnerability exists that could cause arbitrary data to be written to protected locations, potentially leading to escalation of privilege, arbitrary file corruption, exposure of application and system information or persistent denial of service when a low-privileged attacker tampers with the installation folder. | ||||
| CVE-2024-8938 | 1 Schneider-electric | 3 Modicon M340, Modicon Mc80, Modicon Momentum Unity M1e Processor | 2026-04-15 | 8.1 High |
| CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a potential arbitrary code execution after a successful Man-In-The-Middle attack followed by sending a crafted Modbus function call to tamper with memory area involved in memory size computation. | ||||
| CVE-2025-13901 | 1 Schneider-electric | 7 Modicon M241, Modicon M241/m251, Modicon M241 Firmware and 4 more | 2026-03-11 | 5.3 Medium |
| CWE-404 Improper Resource Shutdown or Release vulnerability exists that could cause partial Denial of Service on Machine Expert protocol when an unauthenticated attacker sends malicious payload to occupy active communication channels. | ||||
| CVE-2025-13902 | 1 Schneider-electric | 10 Modicon Controllers M241/m251, Modicon Controllers M258/lmc058, Modicon Lmc058 and 7 more | 2026-03-11 | 5.4 Medium |
| CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause condition where authenticated attackers can have a victim’s browser run arbitrary JavaScript when the victim hovers over a maliciously crafted element on a web server containing the injected payload. | ||||
| CVE-2025-11739 | 1 Schneider-electric | 3 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation, Ecostruxure Power Operation With Advanced Reporting And Dashboards | 2026-03-11 | 7.8 High |
| CWE‑502: Deserialization of Untrusted Data vulnerability exists that could cause arbitrary code execution with administrative privileges when a locally authenticated attacker sends a crafted data stream, triggering unsafe deserialization. | ||||
| CVE-2025-13957 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2026-03-11 | N/A |
| CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause information disclosure and remote code execution when SOCKS Proxy is enabled, and administrator credentials and PostgreSQL database credentials are known. SOCKS Proxy is disabled by default. | ||||
| CVE-2025-13844 | 1 Schneider-electric | 1 Ecostruxure Power Build - Rapsody | 2026-03-03 | 5.3 Medium |
| CWE-415: Double Free vulnerability exists that could cause heap memory corruption when the end user imports a malicious project file (SSD file) shared by the attacker into Rapsody. | ||||
| CVE-2023-6407 | 2 Microsoft, Schneider-electric | 6 Windows 10 1507, Windows 11 21h2, Windows Server 2016 and 3 more | 2026-02-25 | 5.3 Medium |
| A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause arbitrary file deletion upon service restart when accessed by a local and low-privileged attacker. | ||||
| CVE-2018-1124 | 6 Canonical, Debian, Opensuse and 3 more | 13 Ubuntu Linux, Debian Linux, Leap and 10 more | 2025-12-18 | 7.8 High |
| procps-ng before version 3.3.15 is vulnerable to multiple integer overflows leading to a heap corruption in file2strvec function. This allows a privilege escalation for a local attacker who can create entries in procfs by starting processes, which could result in crashes or arbitrary code execution in proc utilities run by other users. | ||||
| CVE-2018-1126 | 5 Canonical, Debian, Procps-ng Project and 2 more | 13 Ubuntu Linux, Debian Linux, Procps-ng and 10 more | 2025-12-17 | N/A |
| procps-ng before version 3.3.15 is vulnerable to an incorrect integer size in proc/alloc.* leading to truncation/integer overflow issues. This flaw is related to CVE-2018-1124. | ||||
| CVE-2014-5413 | 2 Aveva, Schneider-electric | 2 Clearscada, Scada Expert Clearscada | 2025-11-04 | N/A |
| Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 uses the MD5 algorithm for an X.509 certificate, which makes it easier for remote attackers to spoof servers via a cryptographic attack against this algorithm. | ||||
| CVE-2014-5412 | 2 Aveva, Schneider-electric | 2 Clearscada, Scada Expert Clearscada | 2025-11-04 | N/A |
| Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allows remote attackers to read database records by leveraging access to the guest account. | ||||