Filtered by vendor Abb
Subscriptions
Total
230 CVE
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2026-12705 | 1 Abb | 2 Knx Update Tool (abb), Knx Update Tool (bje) | 2026-07-23 | 6.4 Medium |
| Missing support for integrity check vulnerability in ABB KNX Update Tool (ABB), ABB KNX Update Tool (BJE). This issue affects KNX Update Tool (ABB): through 2.0.175; KNX Update Tool (BJE): through 2.0.175. | ||||
| CVE-2025-13162 | 1 Abb | 2 800xa For Advant Master, Control Builder A | 2026-06-24 | 4.4 Medium |
| Uncontrolled Search Path Element vulnerability in ABB Control Builder A, ABB 800xA for Advant Master. This issue affects Control Builder A: through 1.4/4; 800xA for Advant Master: through 6.0.3-1, through 6.1.1-1, 6.1.1-3, 6.2.0-1. | ||||
| CVE-2025-7064 | 1 Abb | 1 Freelance | 2026-06-12 | 6.6 Medium |
| Authentication bypass by primary weakness vulnerability in ABB Freelance. This issue affects Freelance: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, 2019 SP1, 2019 SP1 FP1, 2024. | ||||
| CVE-2025-14771 | 1 Abb | 1 T-mac Plus | 2026-06-04 | 9.9 Critical |
| Files or directories accessible to external parties vulnerability in ABB T-MAC Plus. This issue affects T-MAC Plus: 4.0-24. | ||||
| CVE-2025-14772 | 1 Abb | 1 T-mac Plus | 2026-06-04 | 8.8 High |
| Authorization bypass through User-Controlled key vulnerability in ABB T-MAC Plus. This issue affects T-MAC Plus: 4.0-24. | ||||
| CVE-2025-14773 | 1 Abb | 1 T-mac Plus | 2026-06-04 | 8 High |
| Improper neutralization of input during web page generation ('cross-site scripting') vulnerability in ABB T-MAC Plus. This issue affects T-MAC Plus: 4.0-24. | ||||
| CVE-2025-14774 | 1 Abb | 1 T-mac Plus | 2026-06-04 | 7.4 High |
| Incorrect Authorization vulnerability in ABB T-MAC Plus. This issue affects T-MAC Plus: 4.0-24. | ||||
| CVE-2019-10953 | 5 Abb, Phoenixcontact, Schneider-electric and 2 more | 20 Pm554-tp-eth, Pm554-tp-eth Firmware, Ilc 151 Eth and 17 more | 2026-06-04 | 7.5 High |
| ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets. | ||||
| CVE-2008-2474 | 1 Abb | 1 Pcu400 | 2026-04-23 | N/A |
| Buffer overflow in x87 before 3.5.5 in ABB Process Communication Unit 400 (PCU400) 4.4 through 4.6 allows remote attackers to execute arbitrary code via a crafted packet using the (1) IEC60870-5-101 or (2) IEC60870-5-104 communication protocol to the X87 web interface. | ||||
| CVE-2025-3756 | 1 Abb | 4 800xa System, Symphony + Operations, Symphony Plus Mr (melody Rack) and 1 more | 2026-04-17 | 6.5 Medium |
| A vulnerability exists in the command handling of the IEC 61850 communication stack included in the product revisions listed as affected in this CVE. An attacker with access to IEC 61850 networks could exploit the vulnera bility by using a specially crafted 61850 packet, forcing the communication interfaces of the PM 877, CI850 and CI868 modules into fault mode or causing unavailability of the S+ Operations 61850 connectivity, resulting in a denial-of-service situation. The System 800xA IEC61850 Connect is not affected. Note: This vulnerability does not impact on the overall availability and functionality of the S+ Operations node, only the 61850 communication function. This issue affects AC800M (System 800xA): from 6.0.0x through 6.0.0303.0, from 6.1.0x through 6.1.0031.0, from 6.1.1x through 6.1.1004.0, from 6.1.1x through 6.1.1202.0, from 6.2.0x through 6.2.0006.0; Symphony Plus SD Series: A_0, A_1, A_2.003, A_3.005, A_4.001, B_0.005; Symphony Plus MR (Melody Rack): from 3.10 through 3.52; S+ Operations: 2.1, 2.2, 2.3, 3.3. | ||||
| CVE-2025-8754 | 1 Abb | 1 Zenon | 2026-04-15 | 7.5 High |
| Missing Authentication for Critical Function vulnerability in ABB ABB AbilityTM zenon.This issue affects ABB AbilityTM zenon: from 7.50 through 14. | ||||
| CVE-2025-4676 | 1 Abb | 2 Webpro Snmp Card Powervalue, Webpro Snmp Card Powervalue Ul | 2026-04-15 | 8.8 High |
| Incorrect Implementation of Authentication Algorithm vulnerability in ABB WebPro SNMP Card PowerValue, ABB WebPro SNMP Card PowerValue UL.This issue affects WebPro SNMP Card PowerValue: through 1.1.8.K; WebPro SNMP Card PowerValue UL: through 1.1.8.K. | ||||
| CVE-2025-30171 | 1 Abb | 3 Aspect Enterprise, Matrix Series, Nexus Series | 2026-04-15 | 9 Critical |
| System File Deletion vulnerabilities in ASPECT provide attackers access to delete system files if session administrator credentials become compromised. This issue affects ASPECT-Enterprise: through 3.08.03; NEXUS Series: through 3.08.03; MATRIX Series: through 3.08.03. | ||||
| CVE-2024-48851 | 1 Abb | 1 Flxeon | 2026-04-15 | 7.2 High |
| Improper Validation of Specified Type of Input vulnerability in ABB FLXEON.A remote code execution is possible due to an improper input validation. This issue affects FLXEON: through 9.3.5. | ||||
| CVE-2025-6074 | 1 Abb | 2 Rmc-100, Rmc-100-lite | 2026-04-15 | 6.5 Medium |
| Use of Hard-coded Cryptographic Key vulnerability in ABB RMC-100, ABB RMC-100 LITE. When the REST interface is enabled by the user, and an attacker gains access to source code and control network, the attacker can bypass the REST interface authentication and gain access to MQTT configuration data. This issue affects RMC-100: from 2105457-043 through 2105457-045; RMC-100 LITE: from 2106229-015 through 2106229-016. | ||||
| CVE-2025-12142 | 1 Abb | 1 Terra Ac Wallbox Jp | 2026-04-15 | 6.1 Medium |
| Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33. | ||||
| CVE-2025-4677 | 1 Abb | 2 Webpro Snmp Card Powervalue, Webpro Snmp Card Powervalue Ul | 2026-04-15 | 6.5 Medium |
| Insufficient Session Expiration vulnerability in ABB WebPro SNMP Card PowerValue, ABB WebPro SNMP Card PowerValue UL.This issue affects WebPro SNMP Card PowerValue: through 1.1.8.K; WebPro SNMP Card PowerValue UL: through 1.1.8.K. | ||||
| CVE-2025-12143 | 1 Abb | 1 Terra Ac Wallbox Jp | 2026-04-15 | 6.1 Medium |
| Stack-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33. | ||||
| CVE-2025-2409 | 1 Abb | 3 Aspect Enterprise, Matrix Series, Nexus Series | 2026-04-15 | 9.1 Critical |
| File corruption vulnerabilities in ASPECT provide attackers access to overwrite sys-tem files if session administrator credentials become compromised This issue affects ASPECT-Enterprise: through 3.08.03; NEXUS Series: through 3.08.03; MATRIX Series: through 3.08.03. | ||||
| CVE-2025-10571 | 1 Abb | 1 Ability Edgenius | 2026-04-15 | 9.6 Critical |
| Authentication Bypass Using an Alternate Path or Channel vulnerability in ABB ABB Ability Edgenius.This issue affects ABB Ability Edgenius: 3.2.0.0, 3.2.1.1. | ||||